<strong>1153</strong>- NFPA <strong>Fire</strong>fighter 1 <strong>Performance</strong> <strong>Task</strong><br />
Evaluation Sheet 9-4<br />
Objective:<br />
Force entry through an outward swinging door—Two firefighter<br />
®<br />
method. (NFPA 1001, 5.3.4)<br />
Student Name: Date:<br />
Directions<br />
For this skills evaluation checklist, students will correctly force entry into a structure, given personal<br />
protective equipment, tools, and an assignment,so that the tools are used as designed, the barrier is<br />
removed, and the opening is in a safe condition and ready for entry.<br />
Equipment & Materials<br />
• Full protective clothing • Haligan Tool<br />
• Striking Tool • Outward swinging door or simulator<br />
Criteria & Evaluation Comments<br />
After the candidate has completed the skill sheet, write comments below.<br />
Evaluator/Candidate Comments<br />
Evaluator must initial outcome<br />
Pass<br />
Fail<br />
Evaluator Signature Date Student Signature Date<br />
1. Try before you pry.<br />
<strong>Task</strong> Steps 1 st 2nd<br />
2. FF#1 Place the wedge end of the Haligan tool just above or below the lock.<br />
(if there are two locks, place between the locks)<br />
3. FF#2 Strike the tool using a striking tool in the surface behind the wedge,<br />
driving the wedge into the space between the door and the jamb. (strike<br />
only when FF#1 calls for it)<br />
4. FF#1 Pry down and out with the fork end of the tool making sure the wedge<br />
has been sufficiently driven into the space.<br />