Data Transfer Routines<br />
Name of the Routine<br />
gage_mem_read_master<br />
gage_transfer_buffer<br />
gage_transfer_buffer_3<br />
Description<br />
Reads one sample out of <strong>CompuScope</strong> board’s memory for<br />
channel A of the master <strong>CompuScope</strong> board.<br />
Copies the number of sample points of the <strong>CompuScope</strong><br />
board’s memory space from the specified channel to the<br />
supplied buffer.<br />
Similar to the gage_transfer_buffer_2. Returns an offset<br />
to the beginning of the dword aligned buffer used by the<br />
driver.<br />
Multiple/Independent Mode Routines<br />
Name of the Routine<br />
gage_abort_capture<br />
gage_board_abort_capture<br />
gage_board_force_capure<br />
gage_board_start_capture<br />
gage_force_capture<br />
gage_get_independant_operation<br />
gage_set_independant_operation<br />
gage_start_capture<br />
Description<br />
Used to regain control of the <strong>CompuScope</strong> board(s). This<br />
routine is reconfigured when in Multiple/Independent mode<br />
to work with independent boards. This reconfiguration is<br />
done automatically when the<br />
gage_set_independant_operation routine is called.<br />
Used to regain the control of the selected <strong>CompuScope</strong><br />
board when in Multiple/Independent mode.<br />
Used to force the capture of data by the selected<br />
<strong>CompuScope</strong> board when in Multiple/Independent mode.<br />
Used to force the capture of data by the selected<br />
<strong>CompuScope</strong> board when in Multiple/Independent mode.<br />
Forces the capture of data by the <strong>CompuScope</strong> board(s).<br />
This routine is reconfigured when in Multiple/Independent<br />
mode to work with independent boards. This<br />
reconfiguration is done automatically when the<br />
gage_set_independent_operation routine is called.<br />
Used to check if the boards are in Multiple/Independent<br />
mode or not.<br />
Sets the driver to initialize the Multiple/Independent mode.<br />
Prepares the <strong>CompuScope</strong> hardware for data acquisition.<br />
This routine is reconfigured when in Multiple/Independent<br />
mode to work with independent boards. This<br />
reconfiguration is done automatically when the<br />
gage_set_independent_operation routine is called.<br />
<strong>CompuScope</strong> API Reference <strong>Manua</strong>l 8