gage_board_start_capture<br />

Syntax<br />

C:<br />

void GAGEAPI gage_board_start_capture (int16 mi_board, int16 auto_trigger);<br />

Visual BASIC:<br />

Sub gage_board_start_capture (ByVal mi_board As Integer, ByVal auto_trigger As Integer)<br />

Remarks<br />

gage_board_start_capture has identical functionality to the gage_start_capture routine, but is used to<br />

control <strong>CompuScope</strong>s operating in Multiple Independent mode.<br />

mi_board is used to specify the <strong>CompuScope</strong> to which the command will be applied.<br />

Return Value<br />

None<br />

See also<br />

gage_start_capture, gage_select_board, gage_set_independant_operation, gage_board_force_capture,<br />

gage_board_start_capture and Appendix: Multiple/Independent Mode Operation..<br />

Examples<br />

C:<br />

gage_board_start_capture (mi_board, board.source == GAGE_SOFTWARE);<br />

Visual BASIC:<br />

Call gage_board_start_capture (mi_board, auto_trigger)<br />

<strong>CompuScope</strong> API Reference <strong>Manua</strong>l 16