Multiple Record Mode Routines<br />

Name of the Routine<br />

gage_calculate_mra_addresses<br />

gage_calculate_mr_addresses<br />

gage_multiple_record<br />

gage_multiple_record_acquisitions_32<br />

Description<br />

Corrects the trigger address based on the ETB bit<br />

information located in the data acquired from the card at the<br />

raw calculated trigger address.<br />

Returns the starting, trigger and ending addresses for the<br />

specified channel of the current board to the calling routine.<br />

Allows the application program to force the <strong>CompuScope</strong><br />

hardware to capture only the depth specified when the<br />

trigger event occurs. The card then re-arms automatically<br />

itself to accept another trigger event and record that data<br />

immediately following the first capture.<br />

Sets the number of Multiple Record groups that will be<br />

taken by the <strong>CompuScope</strong> hardware.<br />

Miscellaneous Routines<br />

Name of the Routine<br />

gage_abort<br />

gage_abort_capture<br />

gage_board_type_size_to_text<br />

gage_busy<br />

gage_force_capture<br />

gage_get_error_code<br />

gage_need_ram<br />

gage_normalize_address<br />

gage_power_control<br />

gage_software_trigger<br />

gage_start_capture<br />

gage_triggered<br />

Description<br />

Used to regain control of the <strong>CompuScope</strong> board(s).<br />

Used to regain control of the <strong>CompuScope</strong> board(s).<br />

Returns the pointer to the string that contains the<br />

information about the installed <strong>CompuScope</strong> board.<br />

Determines if <strong>CompuScope</strong> board is busy capturing the data<br />

or not.<br />

Forces the capture of data by the <strong>CompuScope</strong> board(s).<br />

Returns the error code associated with the last call to the<br />

<strong>CompuScope</strong> driver.<br />

Allows the application program to access the <strong>CompuScope</strong><br />

hardware’s RAM buffers.<br />

Calculates the logical address for the <strong>CompuScope</strong><br />

hardware.<br />

Used to control the automatic power management available<br />

on the <strong>CompuScope</strong>s equipped with this feature.<br />

Will trigger the hardware when the trigger source has been<br />

set to GAGE_SOFTWARE.<br />

Prepares the <strong>CompuScope</strong> hardware for data acquisition.<br />

Determines if the <strong>CompuScope</strong> hardware has encountered a<br />

trigger event or not.<br />

<strong>CompuScope</strong> API Reference <strong>Manua</strong>l<br />