<strong>HC25</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

13.2 <strong>AT</strong>+CSIM<br />

s<br />

13.2 <strong>AT</strong>+CSIM Generic SIM Access<br />

<strong>AT</strong>+CSIM allows direct control of the SIM.<br />

Compared to Restricted SIM Access <strong>com</strong>mand <strong>AT</strong>+CRSM, the definition of <strong>AT</strong>+CSIM allows the ME to take more<br />

control over the SIM interface.<br />

However, the SIM Application Toolkit functionality is not supported by <strong>AT</strong>+CSIM. Therefore the following SIM<br />

<strong>com</strong>mands cannot be used: TERMINAL PROFILE, ENVELOPE, FETCH and TEMINAL RESPONSE.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>+CSIM=<br />

Response(s)<br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>+CSIM=, <br />

Response(s)<br />

+CSIM: ,<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Reference(s) PIN USB0-MDM USB0-APP Last<br />

3GPP TS 27.007, 3GPP TS 31.102,<br />

ETSI TS 102 221, GSM 11.11<br />

- + + -<br />

Parameter Description<br />

(num)<br />

Length of or string.<br />

(str)<br />

<strong>Command</strong> passed on by the ME to the SIM.<br />

Parameter length: maximum 260 Bytes.<br />

(str)<br />

Response data of the <strong>com</strong>mand returned by the SIM.<br />

Parameter length: maximum 257 Bytes.<br />

Example<br />

The following examples explain how to use <strong>AT</strong>+CSIM.<br />

<strong>AT</strong>+CSIM=14,"A0A40000027F10"<br />

+CSIM: 4,"9F19"<br />

OK<br />

<strong>AT</strong>+CSIM=14,"A0A40000026F3A"<br />

+CSIM: 4,"9F0F"<br />

OK<br />

<strong>AT</strong>+CSIM=16,"A0C000000F000000"<br />

Select DF-Tele<strong>com</strong><br />

<strong>Command</strong> successful, length '19' of the response<br />

data<br />

Select EF-ADN (Abbreviated dialling numbers)<br />

<strong>Command</strong> successful, length '0F' of the response<br />

data<br />

Get Response<br />

<strong>HC25</strong>_<strong>AT</strong>C_V01.200 Page 230 of 290 7/25/07<br />