<strong>HC25</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

17.2 <strong>AT</strong>^SBV<br />

s<br />

17.2 <strong>AT</strong>^SBV Battery/Supply Voltage<br />

The <strong>AT</strong>^SBV execute <strong>com</strong>mand allows to monitor the supply (or battery) voltage of the module. The voltage is<br />

continuously measured at intervals depending on the operating mode of the RF interface. The duration of a measurement<br />

period ranges from 0.5s in TALK / D<strong>AT</strong>A mode up to 50s when <strong>HC25</strong> is in IDLE mode or Limited Service<br />

(deregistered). The displayed value is averaged over the last measuring period before the <strong>AT</strong>^SBV<br />

<strong>com</strong>mand was executed.<br />

The measurement is related to the test points of B<strong>AT</strong>T+ and GND, both accessible on the bottom of the module.<br />

Refer to [1] for information on the module's test points.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>^SBV=<br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR:<br />

Exec <strong>Command</strong><br />

<strong>AT</strong>^SBV<br />

Response(s)<br />

^SBV: <br />

OK<br />

ERROR<br />

+CME ERROR:<br />

Reference(s) PIN USB0-MDM USB0-APP Last<br />

SIEMENS - + + -<br />

Parameter Description<br />

(num)<br />

Supply (or battery) voltage in mV<br />

<strong>HC25</strong>_<strong>AT</strong>C_V01.200 Page 266 of 290 7/25/07<br />