13.3 <strong>AT</strong>^SCKS<br />

s<br />

13.3 <strong>AT</strong>^SCKS Query SIM and Chip Card Holder Status<br />

This <strong>com</strong>mand controls the SIM connection presentation mode and queries the connection status of the SIM and<br />

the card holder tray of the <strong>HC25</strong>.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>^SCKS=<br />

Response(s)<br />

^SCKS:(list of supported s)<br />

OK<br />

Read <strong>Command</strong><br />

<strong>AT</strong>^SCKS<br />

Response(s)<br />

^SCKS: , <br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Write <strong>Command</strong><br />

<strong>AT</strong>^SCKS=<br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Reference(s) PIN USB0-MDM USB0-APP Last<br />

SIEMENS - + + -<br />

Unsolicited Result Codes<br />

URC 1<br />

^SCKS: <br />

If the <strong>HC25</strong>'s SIM connection status has changed an unsolicited result code (URC) is issued.<br />

URC 2<br />

^SCRD: <br />

If the SIM is not supported by <strong>HC25</strong> and the connection is rejected an unsolicited result code (URC) is issued.<br />

The presentation of this URC cannot be suppressed.<br />

<strong>Command</strong> Description<br />

The read <strong>com</strong>mand returns the URC presentation mode and the status of the SIM card connection.<br />

The write <strong>com</strong>mand enables or disables the presentation of URCs to report the SIM card connection.<br />

If the ME is powered down or reset (<strong>AT</strong>+CFUN or <strong>AT</strong>^SMSO) the current presentation mode setting will<br />

not be retained. Therefore the setting =1 needs to be restored after power on the <strong>HC25</strong>.<br />

Parameter Description<br />

(num)<br />

0 (&F) Suppress unsolicited result code ^SCKS<br />

1 Output unsolicited result codes<br />

<strong>HC25</strong>_<strong>AT</strong>C_V01.200 Page 232 of 290 7/25/07<br />