FORENSIC AND CLINICAL<br />

PRODUCTS FOR FORENSIC AND CLINICAL APPLICATIONS<br />

Ordering Information<br />

Description Quantity Part number<br />

ISOLUTE Confirm HCX 25 mg/1 mL 1,2 100 902-0002-A<br />

ISOLUTE Confirm HCX 50 mg/1mL 2 100 902-0005-A<br />

ISOLUTE Confirm HCX 130 mg/1 mL 3 100 902-0013-A<br />

ISOLUTE Confirm HCX 130 mg/3 mL 3 50 902-0013-B<br />

ISOLUTE Confirm HCX 130 mg/6 mL 4,5 30 902-0013-C<br />

ISOLUTE Confirm HCX 130 mg/10 mL 3 50 902-0013-H<br />

ISOLUTE Confirm HCX 300 mg/6 mL 5 30 902-0030-C<br />

ISOLUTE Confirm HCX 300 mg/10 mL 6 50 902-0030-H<br />

1 Configuration optimized to achieve minimum elution volumes (< 100 µL) with optimized elution solvent<br />

2 Suitable for hydrolysed hair extraction/clean-up<br />

3 Standard configurations for drugs of abuse confirmation testing (up to 5 mL urine sample size)<br />

4 Optimized for gravity loading of solvents and urine samples onto the column<br />

5 Suitable for equine urine extraction<br />

6 Used to extract 5 - 10 mL urine when screening for drugs of abuse<br />

See page 54 for the complete range of ISOLUTE Confirm HCX SPE products<br />

Sample Preparation Methods for Drugs of Abuse<br />

A series of well defined protocols using industry standard 130 mg ISOLUTE Confirm HCX columns is available.<br />

Based on extraction of 5 mL urine samples, high recoveries (> 90%) of all the main DOA classes are ensured.<br />

Extracts are suitable for TLC screening and GC-MS confirmation at the NIDA specified cut-off levels.<br />

Application Notes for ISOLUTE HCX columns<br />

Analyte<br />

Amphetamine and methamphetamine<br />

Barbiturates<br />

Cocaine and benzoylecgonine<br />

Opiates (codeine and morphine)<br />

LSD<br />

Phencyclidine<br />

Fractionation of basic, neutral and acidic drugs of abuse<br />

Application Note<br />

IST1034<br />

IST1032<br />

IST1002<br />

IST1050<br />

IST1041<br />

IST1039<br />

IST1044<br />

Simplified Single Column Methodology for Automated Drugs<br />

of Abuse Testing<br />

Based on the robust chemistry of ISOLUTE Confirm HCX, Biotage has developed a simple, single column<br />

approach that can be used for the extraction of all NIDA-5 (SAMHSA-5) drugs of abuse classes. The SPE<br />

methodology, designed for use with the Caliper LifeSciences RapidTrace uses only eight solvents in total.<br />

Request Application Note IST1081 for more information.<br />