MIXED-MODE SORBENTS<br />
Isolate acidic and basic drugs from biological fluid samples with Biotage’s range of mixed-mode sorbents. The<br />
sorbents provide two primary retention mechanisms, non-polar (hydrophobic) and ion exchange (anion or<br />
cation). The dual retention mechanisms allow the use of rigorous interference elution regimes, providing<br />
extremely clean extracts and reducing matrix effects commonly associated with LC-MS analysis. Technical information<br />
for EVOLUTE and ISOLUTE mixed-mode sorbents are summarized on these pages.<br />
Mixed-mode SPE<br />
Analytes are initially retained by a non-polar retention mechanism, with inorganic salts, polar interferences and<br />
high molecular weight peptides and proteins passing directly through the sorbent bed. The pH is then adjusted<br />
to allow an ion exchange retention mechanism to retain the analyte. Non-polar interferences are removed<br />
using an organic solvent or organic solvent/water wash as shown in Figure 1.<br />
Proteins etc. excluded from<br />
the pores and pass to waste<br />
Salts, phospholipids and<br />
small non-ionizable<br />
interferences are removed<br />
Drugs are eluted<br />
Clean extract<br />
is obtained<br />
Interference Elution 1 Interference Elution 2 Analyte Elution Analysis<br />
Figure 1. The combination of optimized pore structure and additional interference elution steps using<br />
mixed-mode sorbent chemistry guarantees extremely clean extracts.<br />
EVOLUTE CX: Resin-based mixed-mode SPE for Basic Drugs<br />
EVOLUTE CX extracts a wide range of basic drugs from biological fluid samples using a generic procedure,<br />
minimising method development time. The robust mixed-mode sorbent chemistry and optimised pore size<br />
minimises retention of high molecular weight matrix components present in biological fluids. Interferences<br />
including proteins, salts, non-ionisable molecules and phospholipids are removed during the interference elution<br />
step, ensuring extremely clean extracts for LC-MS/MS analysis.<br />
EVOLUTE CX is also available in a larger particle size (50 µm) for more viscous matrices or larger sample<br />
volumes (see pages 25-27 for details).<br />
ISOLUTE HCX, HCX-3 & HCX-5: Silica-based mixed-mode SPE for Basic Drugs<br />
Biotage offers three silica-based mixed-mode sorbents for extraction of basic drugs. Compared to resin based<br />
mixed-mode sorbents, these have reduced non-polar character, and may lead to cleaner extracts. ISOLUTE HCX,<br />
HCX-3 and HCX-5 differ only in their degree of non-polar character, and can be screened in parallel for optimum<br />
extract cleanliness and analyte recovery. For extraction of very polar basic drugs, EVOLUTE CX is<br />
recommended.<br />