6. Initial operation and <strong>system</strong> calibration<br />
6.3.4 Detailed description of<br />
characteristic curve<br />
calibration<br />
Characteristic<br />
curve off<br />
calibrate<br />
Characteristic<br />
curve on<br />
calibrate<br />
Withdrawal<br />
starts<br />
Determining the operating points of the<br />
control <strong>system</strong><br />
■ Manual operation menu<br />
■ Characteristic curve calibration submenu<br />
1x Leave the info menu using the “escape” key<br />
2x<br />
flashes<br />
5x<br />
and then<br />
1x<br />
flashes<br />
1x<br />
2x<br />
1x<br />
Select the menu: manual operation<br />
Select the menu: manual operation<br />
■ select using right key, OFF flashes.<br />
■ Using the upper key, switch to On and<br />
■ confirm twice with the right key.<br />
Calibration procedure starts.<br />
Kindly follow the menu guidance on the<br />
display.<br />
Consecutive drawn amounts of 25 litres,<br />
8 litres and 4 litres are required. After the<br />
relevant operating points of the pump have<br />
been determined and independently logged<br />
into the control <strong>system</strong>, characteristic curve<br />
calibration “on” again appears on the display.<br />
Leave this submenu using the left key.<br />
The characteristic curve calibration is now<br />
complete.<br />