3. Equipment and functional description<br />

■ The freshwater station allows for a hygienic and<br />

energy-saving preparation of warm water via a<br />

stainless steel plate heat exchanger. It provides fresh<br />

hot water for one to two apartment units. The source<br />

of supply is a storage tank with a variable temperature<br />

of 60 to 95°C. At very high storage temperatures<br />

(up to 95°C) a temperature reduction of the<br />

heat transfer media is recommended by admixture.<br />

The primary pump P1 is controlled via block<br />

modulation in such a way that the desired hot water<br />

temperature is kept constant as much as possible.<br />

For the control <strong>system</strong> to calculate the necessary<br />

pump capacity, it uses the heat transfer media<br />

temperature on the primary side, the inlet temperature<br />

of the cold water and the circulation on the<br />

secondary side as well as the current flow.<br />

■ In addition to the preparation of freshwater, the<br />

circulation can also be activated. In the “basic<br />

setting” menu the circulation is switched ON or<br />

OFF.<br />

■ For circulation, up to 3 time slots can be specified in<br />

the “programming” menu.<br />

■ For the stainless steel plate heat exchanger there<br />

are three modes of operation besides the drawing of<br />

hot water:<br />

water temperature-cold, water temperature -hot<br />

and water temperature-timed heating<br />

(See 5.3.3).<br />

4<br />

■ After-run<br />

Should water temperature-cold be selected, it is<br />

possible to set the circulation pump at an after-run,<br />

to allow the stainless steel plate heat exchanger<br />

to cool down and to prevent calcification.<br />

The after-run function is however, only possible and<br />

meaningful outside the circulation time!<br />

■ Activating the hot water controller and reheating<br />

With the additional T5 sensor (not included in<br />

delivery), it is possible to put the control <strong>system</strong> in<br />

operation only after a specified buffer temperature<br />

has been attained. With the T5 sensor it is furthermore<br />

possible to activate a boiler for reheating via a<br />

potential-free contact. Both functions are deactivated<br />

in the factory setting.<br />

■ Disinfection<br />

With this function it is possible to disinfect the<br />

circulation pipes against the danger of legionella.<br />

This function is only activated when a circulation<br />

pipe is available and the circulation has been<br />

switched on.<br />

■ Data logging<br />

With a „data stick” all measured values and the<br />

status of pump outputs can be recorded for a<br />

specific time period. A special computer programme<br />

is used to analyse the measured values at the<br />

freshwater station manufacturer.<br />

T1 = Domestic hot water<br />

T2 = Heat transfer media flow<br />

T3 = Cold water and<br />

circulation temperature<br />

T4 = Heat transfer media return<br />

T5 = Storage tank sensor for<br />

„reheating“ and release of the<br />

hot water controller and<br />

circulation<br />

P1 = Primary heat transfer pump<br />

P2 = Circulation pump<br />

DFZ = Flow rate metre<br />

1 = Heat transfer unit<br />

2 = Return flow preventer<br />

3 = Control<br />

4 = Shut-off valve<br />

5 = Flow rate restrictor 3l<br />

6 = Filling and draining tap<br />

A = Flow heating<br />

B = Return heating<br />

C = Domestic hot water outlet<br />

D = Hot water circulation<br />

E = Cold water (domestic water)