Operation<br />
<strong>MINICOLOR</strong><br />
− Switch on On/Off switch (3, Fig. 5-4)<br />
switch lights up<br />
calibration measurement starts<br />
LED "Motor" (4) lights up<br />
− Switch off On/Off switch at the end of the<br />
calibration time (5 minutes)<br />
switch goes out<br />
dosing screw stops<br />
LED "Motor" (4) goes out<br />
− Weigh calibration quantity in the measuring<br />
bucket<br />
measured calibration quantity<br />
= 170 g in 5 minutes<br />
− Put <strong>MINICOLOR</strong> in production position<br />
(Fig. 5-7)<br />
Fig. 5-7<br />
<strong>MINICOLOR</strong> in production position<br />
3. Calculating the motor speed<br />
Calculating the motor speed W Prod.<br />
W Prod. = Motor speed for production<br />
M SET = Dosing throughput of dosing station<br />
in kg/h preset nominal value of<br />
production<br />
(additive component)<br />
M ACTUAL = Measured calibration quantity in g<br />
t cal. = Actual calibration time in minutes<br />
W Calib = Motor speed for the first calibration<br />
M SET x 1000 x t cal x W Calib<br />
= W Prod<br />
60 x M ACTUAL<br />
Formula 1<br />
Example: i = 30:1<br />
− Calculate the motor speed with formula 1<br />
− Enter 116 in the decade switch (1, Fig. 5-4)<br />
2,16 x 1000 x 5 x 110<br />
60 x 170<br />
= 116<br />
Example<br />
5.1.4 Production with injection moulding machines<br />
− Put dosing station in production position, Fig. 5-7<br />
− Put the control unit to production mode, i.e. put the selector switch (2, Fig. 5-4) to "Prod"<br />
the dosing station operates for so long as an external contact from the injection moulding machine is on<br />
5.6