Operation<br />
<strong>MINICOLOR</strong><br />
5.3.4 Production with extruders<br />
− Calibration is concluded<br />
− Set the selector switch (2, Fig 5-10) to "Ext."<br />
Set the timer to the smallest time unit = 0,1 seconds<br />
the dosing station is operating for so long as an external contact from the extruder is on<br />
5.3.5 Calibration - with injection moulding machines - with <strong>MINICOLOR</strong> S1T control unit<br />
With injection moulding machines (and with cyclical plasticising blow moulding machines), dosing is effected<br />
via a determined runtime of the dosing motor. Dosing is actuated by an external contact from the processing<br />
machine.<br />
Calibration is effected in three working steps:<br />
1. Calculating the dosing throughput of the dosing station in kg/h<br />
− Put the selector switch (2, Fig. 5-13) to "Cont."<br />
− Read motor speed, according to the desired<br />
dosing throughput, from the appropriate<br />
performance/speed scale ( Fig 5-14) and<br />
enter in the decade switch (1, Fig. 5-13)<br />
1<br />
4<br />
3<br />
2<br />
Fig. 5-13<br />
<strong>MINICOLOR</strong> S1T control unit<br />
Dosing screw type G2<br />
Fig. 5-14 Performance/speed scale, example dosing screw type G2, i = 30:1<br />