23.01.2015 Views

OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR

OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR

OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Design and mode of operation<br />

<strong>MINICOLOR</strong><br />

3.2 The various control units<br />

The <strong>MINICOLOR</strong> S control unit is available in<br />

4 versions:<br />

• S1 control unit - for one dosing station<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Fig. 3-2<br />

S1 control unit<br />

• S1T control unit - for one dosing station<br />

with timer<br />

6<br />

Fig. 3-3<br />

S1T control unit<br />

• S2 control unit - for two dosing stations<br />

Fig. 3-4<br />

S2 control unit<br />

• S2T control unit - for two dosing stations<br />

with timer<br />

Fig. 3-5<br />

S2T control unit<br />

Item Description Function<br />

1 Decade switch Sets the speed of the dosing motor<br />

2 Selector switch Sets production mode, calibration or OFF<br />

3 Main switch "On / Off" Switches the power supply for the <strong>MINICOLOR</strong> S control on or off<br />

Lights up in "On" position when mains voltage is applied<br />

4 LED "Motor" (green) Lights up when the dosing motor is operating<br />

5 LED "Alarm" (red) Lights up in case of faults at the dosing motor<br />

6 Timer Sets the dosing time<br />

3.2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!