Design and mode of operation<br />
<strong>MINICOLOR</strong><br />
3.2 The various control units<br />
The <strong>MINICOLOR</strong> S control unit is available in<br />
4 versions:<br />
• S1 control unit - for one dosing station<br />
5<br />
4<br />
3<br />
2<br />
1<br />
Fig. 3-2<br />
S1 control unit<br />
• S1T control unit - for one dosing station<br />
with timer<br />
6<br />
Fig. 3-3<br />
S1T control unit<br />
• S2 control unit - for two dosing stations<br />
Fig. 3-4<br />
S2 control unit<br />
• S2T control unit - for two dosing stations<br />
with timer<br />
Fig. 3-5<br />
S2T control unit<br />
Item Description Function<br />
1 Decade switch Sets the speed of the dosing motor<br />
2 Selector switch Sets production mode, calibration or OFF<br />
3 Main switch "On / Off" Switches the power supply for the <strong>MINICOLOR</strong> S control on or off<br />
Lights up in "On" position when mains voltage is applied<br />
4 LED "Motor" (green) Lights up when the dosing motor is operating<br />
5 LED "Alarm" (red) Lights up in case of faults at the dosing motor<br />
6 Timer Sets the dosing time<br />