OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR
OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR
OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Operation<br />
<strong>MINICOLOR</strong><br />
− Put the <strong>MINICOLOR</strong> in calibration position<br />
(Fig. 5-12)<br />
− Put measuring bucket (1, Fig. 5-12) under the<br />
material outlet<br />
− Switch on the control at the On/Off switch<br />
(4, Fig. 5-10)<br />
switch lights up<br />
− Put selector switch (5, Fig. 5-10) to "Cont."<br />
dosing screw operates<br />
LED "Motor" (6, Fig. 5-10) lights up<br />
− Allow the dosing screw to run until the<br />
granulate is discharged constantly<br />
the dosing sleeve is now filled with material<br />
− Put selector switch (5) to "Prod"<br />
− Press start button (3, Fig. 5-10)<br />
the dosing screw is operating for 300<br />
seconds<br />
LED "Motor" (6, Fig. 5-10) lights up<br />
1<br />
After 300 seconds:<br />
the dosing screw stops<br />
LED "Motor" (6) goes out<br />
− Weigh the calibration quantity in the measuring bucket<br />
(example: 490 g)<br />
− Correct the motor speed and repeat calibration<br />
formula 1<br />
Fig. 5-12<br />
Filling the screw sleeve<br />
Calculating the motor speed W Prod. (formula 1)<br />
W Prod. =Motor speed for production<br />
M SET = Dosing throughput of the<br />
dosing station in kg/h preset<br />
nominal value of production<br />
(additive component)<br />
M ACTUAL =Measured calibration quantity in g<br />
t cal. =Actual calibration time in minutes<br />
W Calib =Motor speed for first calibration<br />
M SET x 1000 x t cal. x W Calib<br />
60 x M ACTUAL<br />
= W Prod.<br />
Formula 1<br />
Example: i = 30:1<br />
Given: - Dosing throughput = 6,0 kg/h<br />
- Motor speed = 300<br />
- Calibration time = 5 min<br />
- Calibration quantity = 490 g<br />
Required: - Motor speed for production<br />
Result: - Motor speed = 306 Example<br />
6,0 x 1000 x 5 x 300<br />
60 x 490<br />
= 306<br />
− Enter the motor speed 306 at the decade switch (8, Fig. 5-10)<br />
− Repeat calibration until the required dosing throughput (calibration quantity 500 g in 5 minutes<br />
6,0 kg/h) has been reached with the set motor speed<br />
5.9