Operation<br />

<strong>MINICOLOR</strong><br />

− Put the <strong>MINICOLOR</strong> in calibration position<br />

(Fig. 5-12)<br />

− Put measuring bucket (1, Fig. 5-12) under the<br />

material outlet<br />

− Switch on the control at the On/Off switch<br />

(4, Fig. 5-10)<br />

switch lights up<br />

− Put selector switch (5, Fig. 5-10) to "Cont."<br />

dosing screw operates<br />

LED "Motor" (6, Fig. 5-10) lights up<br />

− Allow the dosing screw to run until the<br />

granulate is discharged constantly<br />

the dosing sleeve is now filled with material<br />

− Put selector switch (5) to "Prod"<br />

− Press start button (3, Fig. 5-10)<br />

the dosing screw is operating for 300<br />

seconds<br />

LED "Motor" (6, Fig. 5-10) lights up<br />

1<br />

After 300 seconds:<br />

the dosing screw stops<br />

LED "Motor" (6) goes out<br />

− Weigh the calibration quantity in the measuring bucket<br />

(example: 490 g)<br />

− Correct the motor speed and repeat calibration<br />

formula 1<br />

Fig. 5-12<br />

Filling the screw sleeve<br />

Calculating the motor speed W Prod. (formula 1)<br />

W Prod. =Motor speed for production<br />

M SET = Dosing throughput of the<br />

dosing station in kg/h preset<br />

nominal value of production<br />

(additive component)<br />

M ACTUAL =Measured calibration quantity in g<br />

t cal. =Actual calibration time in minutes<br />

W Calib =Motor speed for first calibration<br />

M SET x 1000 x t cal. x W Calib<br />

60 x M ACTUAL<br />

= W Prod.<br />

Formula 1<br />

Example: i = 30:1<br />

Given: - Dosing throughput = 6,0 kg/h<br />

- Motor speed = 300<br />

- Calibration time = 5 min<br />

- Calibration quantity = 490 g<br />

Required: - Motor speed for production<br />

Result: - Motor speed = 306 Example<br />

6,0 x 1000 x 5 x 300<br />

60 x 490<br />

= 306<br />

− Enter the motor speed 306 at the decade switch (8, Fig. 5-10)<br />

− Repeat calibration until the required dosing throughput (calibration quantity 500 g in 5 minutes<br />

6,0 kg/h) has been reached with the set motor speed<br />