OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR
OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR
OPERATING AND MAINTENANCE INSTRUCTIONS MINICOLOR
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Details relating to the unit<br />
<strong>MINICOLOR</strong><br />
2 Details relating to the unit<br />
2.1 Use in accordance with specifications - Function<br />
The <strong>MINICOLOR</strong> pigment mixing unit is exclusively used to meter masterbatch to the main component.<br />
The <strong>MINICOLOR</strong> is fitted between the machine hopper and the machine intake aperture.<br />
The throughflow rate of the materials to be mixed is determined by the material requirement of the<br />
plasticising screw.<br />
2.2 Technical data<br />
2.2.1 Performance data <strong>MINICOLOR</strong><br />
Max. number of dosinging stations ........................................................................................................... 1 or 2<br />
Storage bin volume ................................................................................................................................ 12 liters<br />
Central bin volume ** (main component) ............................................................................................... 20 liters<br />
Operating voltage (switchable) +/-10% ....................................................... I = 230 V, II =115 V, 50-60 Hz<br />
Connected load ....................................................................................................................................... 200 VA<br />
External contact ............................................................................................................................. potential free<br />
Alarm contact ................................................................................................... up to 240 V / 5 A potential free<br />
Weight (with one dosing unit, without control) ........................................................................................... 15 kg<br />
Slide gate** ........................................................................................................................... manually operated<br />
2.2.2 Technical data of the dosing stations<br />
Type<br />
Screw<br />
(dia. mm)<br />
Performance range*<br />
(kg/h)<br />
i = 1:30 i = 1:55**<br />
Weight<br />
(kg)<br />
G 1 12 0,15 - 2,5 0,1 - 1,59 12,9<br />
G 2 20 1,4 - 20 0,7 - 12 13,1<br />
G 3 20 2,7 - 27 1,5 - 20 14,0<br />
* ) Bulk density γ ss = 0,8 kg/dm³<br />
**) Option<br />
2.1