30<br />
® )<br />
<strong>Isis</strong> ®<br />
Electrical <strong>Installation</strong> (cont.)<br />
Before wiring the controller, temporarily attach the mounting plate to the wall box and pull the wires through the center.<br />
CAUTION: The fan must operate on a dedicated circuit with a dedicated neutral. Failure to install the fan on a dedicated<br />
circuit will cause the fan to operate improperly.<br />
(mounted locally to fan)<br />
<br />
10 A 50 Hz<br />
White<br />
Green/<br />
Yellow<br />
Brown<br />
Blue<br />
AC Line/Neutral<br />
(L2/N)<br />
Earth/PE<br />
AC Line (L1)<br />
Wire Color Chart<br />
50/60 Compatible<br />
Power Supply Wire<br />
Color<br />
North America<br />
100–120V System<br />
North America<br />
208–240V System<br />
European Union, United<br />
Kingdom<br />
220–240V System<br />
Australia*<br />
240V System<br />
AC Line (L1)<br />
AC Line/Neutral<br />
(L2/N)<br />
Black White<br />
Black, Red, or<br />
Blue<br />
Brown, Black, or<br />
Grey<br />
Brown or Red<br />
Red, Blue, or<br />
Black<br />
Blue<br />
Black or Light<br />
Blue<br />
Earth/PE<br />
Green or Bare<br />
Copper<br />
Green or Bare<br />
Copper<br />
Green with Yellow<br />
Tracer<br />
Green with Yellow<br />
Tracer<br />
<br />
LED Off “OK”<br />
One 1-Sec. Flash / 5-Sec. Off: Buss Under/Over voltage<br />
Two 1-Sec Flashes / 5-Sec. Off: Motor Over-current<br />
Three 1-Sec. Flashes / 5-Sec. Off: Communication/Motor Stall<br />
Four 1-Sec. Flashes / 5-Sec. Off: Motor Over-temperature<br />
Five 1-Sec. Flashes / 5-Sec. Off: Drive Over-temperature<br />
* Note: If installing the fan in Australia, a licensed electrician must perform the electrical installation.<br />