BATTERY RETAINER<br />

BRACKET<br />

(TB1)<br />

INPUT<br />

CIRCUIT BREAKER<br />

(CB1)<br />

DC FUSE (F3)<br />

BATTERY<br />

INTERCONNECT<br />

(TB3)<br />

POS. +<br />

NEG. -<br />

7 8 9 10 11 12<br />

INVERTER CABINET<br />

76"H x 48"W x 30"DP.<br />

ELECTRONICS<br />

COMPARTMENT<br />

X<br />

BATTERY<br />

INTERCONNECT<br />

+<br />

-<br />

REV. DES<strong>CR</strong>IPTION DATE BY<br />

2<br />

CAUTION:<br />

DATE:<br />

1-<br />

3-<br />

2-<br />

4-<br />

BEFORE WIRING TO INVERTER,<br />

TURN INSTALLATION SWITCH TO OFF<br />

AND REMOVE DC FUSE.<br />

CUT ITEMS 3 - 5 TO MINIMUM LENGTH.<br />

OBSERVE POLARITY, CONNECT BATTERIES<br />

AS SHOWN.<br />

FOLLOW START-UP PROCEDURE IN<br />

SYSTEM MANUAL.<br />

ALL DIMENSIONS ARE SHOWN IN INCHES DRAWN BY:<br />

ALL DIM. TOL. .015", ANGULAR ALL DIM. TOL. 1ALL DIM. TOL.<br />

UNLESS OTHERWISE SPECIFIED. APPROVED BY:<br />

08/23/05<br />

144VDC<br />

SCHEMATIC<br />

12VBATTERIES<br />

3 CABLE 6 GA. "LG.<br />

2 66<br />

1 INTERCONNECT<br />

ITEM<br />

NO.<br />

DES<strong>CR</strong>IPTION<br />

12<br />

- +<br />

+<br />

-<br />

+<br />

-<br />

NOTE:<br />

REMOVE BATTERY RETAINER BRACKET BEFORE<br />

AND REPLACE AFTER BATTERY INSTALLATION<br />

INSTALLATION SW<br />

DISCHARGE SW<br />

PRE-CHARGE SW<br />

8<br />

1<br />

4<br />

+<br />

-<br />

+<br />

-<br />

+<br />

+<br />

-<br />

-<br />

1 2 3 4 5 6<br />

6 7<br />

DOORS, COVERS OMITTED FOR CLARITY<br />

7 8 9 10 11 12<br />

1 2 3 4 5 6<br />

TOP VIEW OF BATTERIES<br />

SHOWN ABOVE<br />

6 BATTERIES PER SHELF<br />

ON 2 SHELVES<br />

3<br />

5<br />

8<br />

4.0kVA @ 90 MINUTE RUN TIME<br />

BATTERY<br />

BATTERY INTERCONNECT, "C-/C3-3R", FRONT MOUNT<br />

4.0kVA @ 90 MIN.<br />

SL-12105<br />

12<br />

10<br />

QTY.<br />

BAT-CG12105<br />

4 CABLE 6 GA. 48"LG. 1 W-B048+060L1<br />

PART NO.<br />

DRAWING NUMBER:<br />

K W<br />

303404<br />

1 - +<br />

MANUFACTURER PROVIDED<br />

7 FUSE BLOCK 1 F-B060-0250<br />

6 FUSE 1 FNLN050250B<br />

5 CABLE 6 GA. 60"LG. 1 W-B060+060B0<br />

36 1 W - B 0 3 6 + 0 6 0 L 1<br />

CABLE 6 GA. "LG. 1 W-B066+060L2<br />

SCALE: 1 = 15<br />

+ - +<br />

- - +<br />

+ -<br />

- +<br />

- +<br />

X X X<br />

AC INPUT AC OUTPUT<br />

(TB2)<br />

26<br />