Calculation Formula for Horizontal, Vertical and Gradient Conveyance<br />

The maximum static tension acting on the <strong>chain</strong> can be calculated from the following formula.<br />

Specifications of conveyor<br />

Unit<br />

T : Max. tension applied to the <strong>chain</strong> kN<br />

Q : Max. conveyance capacity t/h<br />

S : Conveyance speed m/min<br />

V : Vertical center distance between sprocket shafts m<br />

H : Horizontal center distance between sprocket shafts m<br />

L : Center distance between sprocket shafts m<br />

M : Weight of traveling parts (weight of <strong>chain</strong>, slats, buckets, etc.) k/m<br />

f1 : Coefficient of friction between <strong>chain</strong> and guide rail<br />

f2 : Coefficient of friction between conveyed articles and bottom and/or side plates<br />

: Mechanical transmission efficiency of drive<br />

kW : Required power<br />

kW<br />

g : Gravitational acceleration 9.80665m/S 2<br />

W : Total weight of conveyed articles on the conveyor (maximum value)<br />

k<br />

L (m)<br />

Countable objectW<br />

Weight per unit of loadsk<br />

Intervals of loads (m)<br />

Load type <br />

Horizontal<br />

Vertical<br />

Gradient<br />

Conveys loads on it<br />

Slat conveyor, apron<br />

conveyor, etc.<br />

<br />

<br />

Conveys by scraping<br />

Continuous flow conveyor,<br />

scraper conveyor, etc.<br />

<br />

<br />

Conveys loads on it<br />

Bucket elevator,<br />

tray elevator, etc.<br />

<br />

<br />

Conveys loads on it<br />

Slat conveyor,<br />

apron conveyor, etc.<br />

<br />

<br />

Countable<br />

object<br />

Bulk<br />

Bulk<br />

Countable<br />

object<br />

Bulk<br />

Countable<br />

object<br />

Bulk<br />

g<br />

1,000<br />

T(W2.1ML)f1<br />

kW<br />

TS<br />

5,320<br />

Q<br />

T(16.7 2.1M)Lf1<br />

S<br />

kW<br />

TS<br />

5,320<br />

T(16.7<br />

kW<br />

Q<br />

S<br />

TS<br />

52.2<br />

T(WML)<br />

kW WLS<br />

52.2<br />

Q<br />

T(16.7<br />

S<br />

kW<br />

TS<br />

52.2<br />

f22.1Mf1)L<br />

g<br />

1,000<br />

M)(L2)<br />

g<br />

1,000<br />

g<br />

1,000<br />

g<br />

1,000<br />

Hf1V g<br />

T(WML)<br />

<br />

L 1,000<br />

g<br />

1.1M(Hf1V)<br />

1,000<br />

S<br />

g<br />

kW TM(VHf1)<br />

1,000<br />

<br />

52.2<br />

Q<br />

g<br />

T(16.7 M)(Hf1V)<br />

S<br />

1,000<br />

g<br />

1.1M(Hf1V)<br />

1,000<br />

S<br />

g<br />

kW TM(VHf1)<br />

1,000<br />

<br />

52.2<br />

Technical Data<br />

Conveys by scraping<br />

Continuous flow conveyor,<br />

scraper conveyor, etc.<br />

<br />

<br />

Bulk<br />

Q<br />

g<br />

T16.7 (Hf2V)<br />

S<br />

1,000<br />

g<br />

M(Hf1V)<br />

1,000<br />

g<br />

1.1M(Hf1V)<br />

1,000<br />

S<br />

g<br />

kW TM(VHf1)<br />

1,000<br />

<br />

52.2<br />

Chain Selection<br />

Note: If the results of H f1 - V and/or V -H f1 are less than zero,<br />

adopt zero for those values.<br />

About 10% power loss was estimated and included in the value 52.2 used in the above formulas.<br />