230 CHAPTER 19. ADVANCED SLICING<br />

• slicer to cia doesn’t compile. . .<br />

That is because a COMMON block is not defined. You probably exited IDL after having<br />

sliced a big file, and you tried to read your .sli file. . . Reread carefully Section 19.6.8 or<br />

type the following commands:<br />

CIA> COMMON slicer_data, Oh_my_God_what_a_stupid_name_for_a_variable<br />

CIA> .run slicer_to_cia<br />

19.6.11.3 x slicer did not do what I told it to do. . .<br />

• x slicer did not write the SCDs where it was told to. . .<br />

Are you sure that you hit the return key after entering the path in the directory field ?<br />

Remember that the default directory is the one from which you launched x slicer.<br />

• x slicer did not create all the SCDs I asked for. . .<br />

You probably asked for SCDs of 1 frame: as they do not exist, they were not created.<br />

19.6.11.4 x slicer crashes. . .<br />

• x slicer crashes just in the beginning. . .<br />

You should probably reread the section about x slicer customization, because you probably<br />

made a mistake in entering your preferred directory.<br />

• x slicer crashes while creating SCDs. . .<br />

You probably asked it to build a SCD with no frames, or with a hole in it (by misusing<br />

the merge buttons).<br />

• x slicer crashes while saving SCDs. . .<br />

Are you sure you have enough place on your disk? Or even the right to write on it?