2.5.6 Analyze<br />
Analyze Screens<br />
Options Screen<br />
ANALYZE displays tool and controller diagnostic information, traces and I/O status.<br />
<strong>User</strong> <strong>Manual</strong><br />
TOOL tab<br />
This tab shows live status of the following<br />
events. It is updated every millisecond. Use<br />
this tab to perform diagnostics during<br />
troubleshooting operations.<br />
Transducer Health – The thickness of the<br />
vertical line within the horizontal bar<br />
indicates transducer health. The thicker the<br />
line the less healthy. Once the line reaches<br />
the tick mark, on either side of center, the<br />
transducer zero shift can no longer be<br />
compensated for and the transducer needs to<br />
be replaced.<br />
Transducer Torque – Provides a live<br />
transducer torque value during the tightening<br />
cycle.<br />
Transducer Current – The transducer is<br />
powered with a constant current value. This<br />
current should be present and not varying.<br />
See section 2.3 for limits.<br />
<strong>Controller</strong> DC Bus voltage – The bus should<br />
always be around 320 VDC.<br />
<strong>Controller</strong> AC Supply Voltage / Frequency –<br />
See section 1.3 for controller AC volts<br />
specification.<br />
Tool Temperature – Temperature is not<br />
measured during tool operation. Interacts<br />
with the Temperature Limit parameter. See<br />
section 2.5.3/TOOL tab.<br />
Tool Output Angle – number of circular<br />
degrees of rotation on the output of the tool.<br />
Resets at each start.<br />
Tool Output Speed – Real time speed of the<br />
output of the tool.<br />
30