09.07.2015 Views

Carrier Compressors Service Guide

Carrier Compressors Service Guide

Carrier Compressors Service Guide

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

-------††††††††††3.0 – COMPRESSOR AND PARTS DATA3.1 – 06D Series <strong>Compressors</strong> – Physical Data (page 1 of 2)CARRIER/CARLYLEMODELNUMBER06DM8080...06DR1090...06DR0130...06DM3130...06DR3160...06DM3160...06DR7180...06DA8182...06DR8200...06DR7240...06DR7250...06DA8242...06DA8252...06DR2280...06DA3282...06DR3370...06DM3370...06DA5372...06DR5410...STANDARDSERVICEREPLACEMENTMODEL06DM8086...06DR1096...(b)06DR0136...(c)06DM3136...(c)06DR3166...(c)06DM3166...(c)06DR7186...06DA8186...06DR8206...06DR7246...06DR7256...06DA8246...06DA8256...06DR2286...06DA3286...06DR3376...06DM3376...06DA5376...06DR5416...SUCTIONTEMPERATURERANGER-404A/507& R-502R-134a& R-1 2R-2 2Deg.5 - - FDeg.CDeg.FDeg.CDeg.FDeg. C0 to 50 -18 to 10-0 to 5 -18 to-40 to 0* -40 to -18* -10 to 55 -23 to 13 -35 to 5 0 -37 to-40 to 0* -40 to -18* -10 to 55 -23 to 13 -35 to 0 -37 to0 to 50 -18 to 100 to 45-18 to-40 to 25* -40 to -4* -10 to 55 -23 to 13 -35 to 25 -37 to0 to 25 -18 to -4 -10 to 55 -23 to 13 0 to 45-18 to-40 to 0* -40 to -18* -10 to 55 -23 to 13 -35 to 0 -37 to0 to 50 -18 to 100 to 55 -18 to-40 to 40* -40 to 4* -10 to 55 -23 to 13 -40 to 25 -40 to-40 to 25* -40 to -4* -10 to 55 -23 to 13 -40 to 25 -40 to-40 to 25* -40 to -4* -10 to - 55 -23 to - 13 -40 to 25 -40 to0 to 50 -18 to 100 to 55 -18 to0 to 50 -18 to 100 to 55 -18 to-40 to 25* -40 to -4* -10 - to 5 -23 - to 1 -40 to 25 -40 to0 to 50 -18 to 103 0 to 55 -18 to-40 to 25* -40 to -4* -10 to 55 -23 to 13 -40 to 25 -40 to0 to 25 -18 to 10 -10 to - 55 -23 to - 13 0 to 45-18 to0 to 50 -18 to 100 to 55 -18 to-40 to 25* -40 to -4*-40 to 25 -40 to...(a)††††††††††13-18-187-47-1813-4-4-41313-413-4713-4* Cylinder head fan required at SST of -20 Deg. F. (-29 deg. C.) and below for R-404A/R-507 and R-502.† Cylinder head fan required at SST of 0 Deg. F. (-18 deg. C.) and below for R-22.(a) Approximate condensing temperature ranges. CHECK ACTUAL PERFORMANCE DATA FOR ANY NEW APPLICATION,ESPECIALLY AT OR NEAR UPPER OR LOWER LIMIT: L.T.=70 to 120 Deg.F. (21 to 49 Deg.C.), M.T.=80 to 130 Deg.F.(27 TO 54 Deg.C.) and H.T. (R-22 only) = 80 TO 150 Deg.F. (27 to 66 Deg.C.).(b) The 06DR 109 single phase compressor has a 3 HP (2.2 kW) motor.(c) <strong>Service</strong> compressors have dual suction service valve locations, one on motor end and one near the oil pump.62

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!