LNC-M520iOP Panel Operation3.4 CYCLE STARTAfter key-in a program, switching the operation mode to MEM or MDI mode and pressing“CYCLE START” button to executing programs. While the program is executed, this lightwill be ON. The timings of using “CYCLE START” button are the following:a. Auto executing in MEM mode:When a program is selected in MEM mode, pressing “CYCLE START” button to executethe program. The light will remain ON during program executing time until the programexecution is finished.Before executing program, the three axes must return to the reference point. If notreturning back to the reference point, users can switch the “Reference Need to OFF” onthe Users Define screen. By doing this, program will be able to execute without returningback to the reference point.b. Auto executing in MDI mode:Users can key-in a block of program commanding such as G91 G01 X100. Z100 in MDImode. Then pressing “CYCLE START” button to execute this single block command.The intension of this executing mode is different than that of MEM mode, which isalways used in testing some motion. The light will remain ON during executing time untilthe executing is finished.LNC Technology Co., Ltd. 115