– B.8 –<br />

Fig. B.1 Example of a computational domain having (17 �11 � 7) cells and<br />

7 boundary specifications.<br />

Consider a computational domain shown in Fig. B.1. There are 17 �11 � 7 cells in the x,<br />

y, and z directions, respectively. The corresponding number of cell vertices is thus<br />

18 �12 � 8 and of nodes is 19 �13 � 9. In data #28 (nx, ny, nz) of the KECONTROL, the<br />

following values are specified:<br />

#28: 18 12 8<br />

There are 7 boundary types: B1 (blocked cells), B2 (inlet), B3 (outlet), B4 (channel side<br />

wall), B5 (symmetry plane), B6 (channel bed), and B7 (water surface). In data<br />

#36 (nrbnd) of the KECONTROL, the following is specified:<br />

#36: 7<br />

This input is then followed by 3-lines boundary specifications, #37 (cbnd 1, cbnd 2),<br />

#38 (istart, iend, jstart, jend, kstart, kend), and #39 (rks), to be inputted for each<br />

boundaries. The boundary type (cbnd 1) is either: