12.07.2015 Views

PA7300 Instruction Manual - TECO-Westinghouse Motor Company

PA7300 Instruction Manual - TECO-Westinghouse Motor Company

PA7300 Instruction Manual - TECO-Westinghouse Motor Company

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FunctionEnergy-SavingTuningoperationEnergy-SavingCoefficientK2ParameterNo.Cn-49Cn-50Cn-51Cn-52Cn-53Cn-54Cn-55Cn-56Cn-57Cn-58Cn-59Cn-60NameTuning Operation VoltageLimitTuning Operation ControlCycleTuning Operation Volt.Step (100% output Volt)Tuning Operation Volt.Step (5% output Volt)Not usedNot usedNot usedNot usedNot usedEnergy-Saving CoefficientK2 (60Hz)Energy-Saving CoefficientReduction ratio (6Hz)<strong>Motor</strong> Code Cn-61 Not usedRetry time Cn-62 Auto Restart Time Interval<strong>Motor</strong>OverheattimeCn-63<strong>Motor</strong> Overheat protectiontime*1 For 220V class. × 2 for 440V class.LCD Display(English)Cn-49=00%Sav. Tuning V_LimitCn-50=01.0sSav. Tuning periodCn-51=00.5%Sav. Tuning Gain 1Cn-52=00.2%Sav. Tuning Gain 2Cn-53=00.000ReservedCn-54=00.000ReservedCn-55=00.000ReservedCn-56=00.000ReservedCn-57=000.00ReservedCn-58=115.74* 6Eg. Saving CoeffCn-59=100%K2 Redunce RatioCn-60=29* 4440V 25HPCn-61=000ReservedCn-62=00sRetry timeCn-63=060s<strong>Motor</strong> OH timeSetting RangeSettingUnitFactorySetting020% 1% 0%0.110.0s 0.1s 1.0s0.110.0% 0.1% 0.5%0.110.0% 0.1% 0.2%Ref.Page6100.00000.000 00.00000.000 00.00000.000 00.00000.000 000.00000.00 0.00655.35 0.01 115.74* 650100% 1% 100%616200FF 29* 8 62000~000 020s 1s 0s 631300s 1s 60s 63*2 For 220V class. × 2 for 440V class.*3 Setting range becomes 10 to 200% of inverter rated current. The factory setting base on <strong>TECO</strong> AEEFstandard 4 poles motor, 220V/60Hz, 440V/60Hz.*4 Factory settings differ depending on inverter capacity (Sn-01 set value).This example shows combination of <strong>TECO</strong> standard motor 440V 60Hz 25HP (18.5KW).(Refer to the table on page 69)At setting Sn-01, the set value changes to the factory setting. For any application other than <strong>TECO</strong>standard motors, set the value shown on the nameplate of the motor.*5 Factory setting and setting, range differ depending on inverter capacity (Sn-01 set value).*6 Differs depending on Cn-60 set value.*7 Factory setting differ depending on V/F curve selection (Sn-02).*8 The same value as Sn-01 is set.51

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!