3 Sn-04=10 XX Full-range DC injection braking stopDC injection braking time differs by the output frequency when stop command isinput as shown below.RUN COMMANDOUTPUT FREQUENCYCLOSEDOPENDC INJECTIONBRAKING TIMECUTOFF OFINVERTEROUTPUT (Cn-40 setting value)DC INJECTIONBRAKING TIMECn-12×10DC INJECTION BRAKINGTIME AT STOP (Cn-12)10% SPEED 100% SPEEDOUTPUT FREQUENCY WHEN STOPREFERENCE IS INPUT4 Sn-04=11 XX Coasting to a Stop (timer function provided)Once stop command is input, run command is disregarded during T 1 time.CLOSEDRUN COMMANDOUTPUT FREQUENCYOPENCLOSEDWHEN STOP REFERENCEIS INPUT, INVERTEROUTPUT IS CUTOFFT 1 TIMEDECELERATION TIMET 1 TIME100% SPEEDOUTPUT FREQUENCY WHENSTOP REFERENCE IS INPUT75