2. PRINTER SETUP ENGLISH VERSION EO1-330582.9 Setting an Operating Environment2.9.1 Parameter Setting(Cont.)(22) Ribbon Near End SelectionThis parameter is to choose the remaining ribbon length where the ribbonnear end is detected.When “PARAMETER SET” appears, press the [PAUSE] key untilthe following display appears”.PARAMETER SETRBN NEAR END 70mUse the [FEED] or [RESTART] key to select a desired option.[RESTART][FEED]RBN NEAR END 70mNear end is detected when the remainingribbon is 70m long.RBN NEAR END 30mNear end is detected when the remainingribbon is 30m long.RBN NEAR END OFFRibbon end is not detected.After selecting the ribbon near end function, press the [PAUSE] key.(23) Expansion I/O Interface Type SelectionThis parameter is to choose a type of the Expansion I/O interfaceoperating mode.This parameter should be set depending on the expansion I/O controlspecification of the device to be connected via the expansion I/Ointerface. For details, refer to the External Equipment InterfaceSpecification.When “PARAMETER SET” appears, press the [PAUSE] key untilthe following display appears.PARAMETER SETEX.I/O TYPE1Use the [FEED] or [RESTART] key to select a desired option.[RESTART][FEED]EX.I/O TYPE1EX.I/O TYPE2TYPE1: Standard modeTYPE2: Inline modeAfter selecting an Expansion I/O Interface type, press the [PAUSE] key.E2-27