12.07.2015 Views

Allegro RED Owner's Manual - Tiffin Motorhomes

Allegro RED Owner's Manual - Tiffin Motorhomes

Allegro RED Owner's Manual - Tiffin Motorhomes

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TIFFIN MOTORHOMES –ALLEGRO <strong>RED</strong>® Chapter 7 ELECTRICAL FEATURESCautionFailure to turn “off” the 120 VAC appliances when starting or stopping the generator maydamage the transfer switch and/or electrical appliances.For more detailed operating instructions and to determine necessary preventive-maintenance schedules andprocedures, review the manufacturer owner’s manual.Automatic Transfer SwitchThe automatic transfer box switches AC power from shore to generator to the coach main distribution panel. This isachieved by the closing and opening of contactors that are located in the box interior (see diagram on AutomaticTransfer Switch which is located in owner’s information package). Power from shore is fed through contacts located onR4 and R5. Power input is sensed by electrical board B1. If shoreline neutral is present it will allow relay R1 to energizewhich energizes relays R2 and R3 applying shore power to the main control box located in the motor home. If the unitsenses that an open neutral condition exists, R1 will not energize not allowing the coach to receive the potentiallyappliance damaging voltage. Power from the generator is sensed by board B1 and after a delay of 15-20 seconds; R4and R5 energize automatically disconnecting shore power B1checks for generator neutral and if present allow R2 andR3 to energize allowing generator power to the main control panel.CautionService to this box is to be done by a qualified technician. DO NO attempt toremove cover unless shore cord is unplugged and generator is off.If the unit is plugged into shore but no power to coach then make sure the shore outlet has power. Ifpower is present this may indicate the unit is sensing an open neutral condition. Start the generator. If power isrestored to the coach then neither the shore plug or outlet may be defective (the neutral line may be broken).If there is no power to coach from shore or generator then check the generator circuit breaker. If the circuitbreakers are not tripped in generator or coach, replace transfer box.For more detailed information on the automatic transfer switch, please refer to the specific owner’s instructionsfound in the owner’s information package.7-10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!