<strong>CH</strong>-<strong>TRAMPAC</strong> Document Rev. 2, May 2005SECTION 4: MEASUREMENT1. Decay Heat Plus Error (W) ___________________Wattage Limit for TRUPACT-II or HalfPACT Design Pressure Limit___________________Decay Heat Plus Error ≤ Wattage Limit for TRUPACT-II or HalfPACTDesign Pressure LimitYES / NO2. Calculated Flammable Gas Generation Rate (FGGR) (mol/sec) ___________________3a. Maximum Allowable Hydrogen Gas Generation Rate<strong>of</strong> Container (mol/sec)___________________Calculated FGGR ≤ Maximum Allowable Hydrogen GasGeneration Rate <strong>of</strong> ContainerYES / NO3b. Calculated Innermost Confinement Layer Flammable GasConcentration (vol%)___________________Mixture Lower Explosive Limit (MLEL) (vol %)Calculated Innermost Confinement Layer Flammable GasConcentration Plus Sum <strong>of</strong> Flammable VOCs (InnermostConfinement Layer Concentration) (vol %)______________________________________Calculated Innermost Confinement Layer Flammable GasPlus Flammable VOCs ≤ MLELYES / NO5.2-51