<strong>CH</strong>-<strong>TRAMPAC</strong> Document Rev. 2, May 20052.5.2 Methods <strong>of</strong> Compliance and VerificationCompliance shall be by one, or a combination, <strong>of</strong> the following methods:• Administrative and procurement controls demonstrating that filter vents have beenprocured to the specifications <strong>of</strong> Section 2.5.1.• Visual inspection to the specifications <strong>of</strong> Section 2.5.1.• Sampling by measurement <strong>of</strong> filter characteristics to the specifications <strong>of</strong> Section 2.5.1.If sampling by measurement is selected as the compliance method, the test methods used todetermine the compliance <strong>of</strong> filter vents or equivalent venting mechanisms with the minimumperformance-based requirements specified in Table 2.5-1 and this section shall be directed byprocedures under a QA program. For equivalent venting mechanisms, compliance with theminimum total hydrogen diffusivity per container type specified in Table 2.5-1 shall bedemonstrated through documentation for the equivalent venting mechanism used.2.5-3