12.07.2015 Views

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>DC3500</strong> <strong>AT</strong> <strong>Commands</strong> Reference <strong>Manual</strong> <strong>500242R01</strong>5.11. Select bearer service type +CBSTDescriptionThis set command selects the bearer service with data rate , and the connectionelement to be used when data calls are originated.SyntaxCommand syntax: <strong>AT</strong>+CBST=[[,[,]]]CommandPossible response(s)<strong>AT</strong>+CBST=5,0,1OKorCME ERROR: Read command+CBST: ,,<strong>AT</strong>+CBST?Test command<strong>AT</strong>+CBST=?OK+CBST: (list of supporteds),(listof supported s),(list ofsupporteds)OKDefined values data rate may be:- 0: autobauding- 4: 2400 bps (V.22bis)- 5: 2400 bps (V.26ter)- 6: 4800 bps (V.32)- 7: 9600 bps (V.32)- 12: 9600 bps (V34); supported only for R<strong>AT</strong>_UMTS;- 14: 14400 bps (V34); supported only for R<strong>AT</strong>_UMTS;- 15: 19200 bps (V34); supported only for R<strong>AT</strong>_UMTS;- 16: 28800 bps (V34); supported only for R<strong>AT</strong>_UMTS;- 17: 33600 bps (V34); supported only for R<strong>AT</strong>_UMTS;- 68: 2400 bps (V110 or X.31 flag stuffing)- 70: 4800 bps (V110 or X.31 flag stuffing)- 71: 9600 bps (V110 or X.31 flag stuffing)- 75: 14400 bps (V110 or X.31 flag stuffing); supported only for R<strong>AT</strong>_UMTS;- 79: 19200 (V110 or X.31 flag stuffing); supported only for R<strong>AT</strong>_UMTS;- 80: 28800 (V110 or X.31 flag stuffing); supported only for R<strong>AT</strong>_UMTS;- 81: 38400 (V110 or X.31 flag stuffing); supported only for R<strong>AT</strong>_UMTS;- 82: 48000 (V110 or X.31 flag stuffing); supported only for R<strong>AT</strong>_UMTS;- 83: 56000 bps (V.110 or X.31 flag stuffing; this setting can be used in conjunction withsynchronous non-transparent UDI or RDI service in order to get FTM); supported only forR<strong>AT</strong>_UMTS;- 84: 64000 bps (X.31 flag stuffing; this setting can be used in conjunction with asynchronousnon-transparent UDI service in order to get FTM); supported only for R<strong>AT</strong>_UMTS;- 115: 56000 bps (bit transparent); supported only for R<strong>AT</strong>_UMTS;- 116: 64000 bps (bit transparent); supported only for R<strong>AT</strong>_UMTS;- 130: 28800 bps (multimedia); supported only for R<strong>AT</strong>_UMTS;- 131: 32000 bps (multimedia); supported only for R<strong>AT</strong>_UMTS;- 133: 33600 bps (multimedia); supported only for R<strong>AT</strong>_UMTS;- 134: 64000 bps (multimedia); supported only for R<strong>AT</strong>_UMTS; bearer service may be:- 0: datacircuit asynchronous (UDI or 3.1 kHz modem); supported only for R<strong>AT</strong>_UMTS;- 1: data circuit synchronous (UDI or 3.1 kHz modem); supported only for R<strong>AT</strong>_UMTS;- 5: data circuit synchronous (RDI); supported only for R<strong>AT</strong>_UMTS; connection element may be:- 0: transparent- 1: non-transparent- 2: both, transparent preferred- 3: both, non-transparent preferredConfidential DAVISCOMMS (S) PTE LTD 25 /136

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!