12.07.2015 Views

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>DC3500</strong> <strong>AT</strong> <strong>Commands</strong> Reference <strong>Manual</strong> <strong>500242R01</strong>7.16. Clock +CCLKDescriptionThis set command sets the real-time clock of the ME.SyntaxCommand syntax: <strong>AT</strong>+CCLK=Command<strong>AT</strong>+CCLK=”02/07/01,14:54:00”Note: set date to July 1-st, 2002 and time to 14:54Read command<strong>AT</strong>+CCLK?Test command<strong>AT</strong>+CCLK=?Possible response(s)OKorCME ERROR: +CCLK: “02/07/01,14:55:00”OKOKDefined values: string type value; format is “yy/MM/dd,hh:mm:ss+TZ”, wherein characters indicates year,month, day, hour, minutes, seconds.TZ: Time zone information represented by two digits. The time zone information is optional;if it was entered it is always accepted, but the display of TZ for query contains this information (inupdated form) only if the network supports the time zone information.7.17. Alarm +CALADescriptionThis set command sets an alarm time in the MT. There can be an array of different types of alarms. Ifsetting fails, a CME ERROR: is returned. To set up a recurrent alarm for more days in theweek, the parameter is used.When an alarm is timed out, the alarm actions are executed:- sound alarm (if not silent)- unsolicited alarm code +CALV: is displayed on DTESyntaxCommand syntax: <strong>AT</strong>+CALA=[,[,[,[,[,]]]]]Possible response(s)Command<strong>AT</strong>+CALA=”02/07/01,14:56:00 OK+04”,1,1,”Alarmor”CME ERROR: Read command<strong>AT</strong>+CALA?Test command<strong>AT</strong>+CALA=?[+CALA: ,,,[],[],[+CALA:,,,[],[],[...]]]i.e. +CALA: ”02/07/01,14:56:00+04”,1,1,”Alarm”,0OK+CALA: (list of supported s),(list of supporteds),,,(list of supported ’s)OKDefined values: string type value; format is “yy/MM/dd,hh:mm:ss+tz”, wherein characters indicates year,month, day, hour, minutes, seconds and time zone.Note: if the parameter is used, the parameter must not contain a date., , : integer type value indicating the index of the alarm, the allowed range of indexesare 1-3; if not indicated by user, default value 1 is assumed;Confidential DAVISCOMMS (S) PTE LTD 63 /136

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!