12.07.2015 Views

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

DC3500 AT Commands Manual 500242R01 ... - Cooking Hacks

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DC3500</strong> <strong>AT</strong> <strong>Commands</strong> Reference <strong>Manual</strong> <strong>500242R01</strong>7.9. Display control +CDISDescriptionThis set command is used to write the contents of MT text type display elements. An element canconsist of one or several characters. The order of element parameters should follow the rule:first is the element in upper left corner, second is the element to the right and so on.SyntaxCommand syntax: <strong>AT</strong>+CDISCommand<strong>AT</strong>+CDIS=[[,[,...]]]Read command<strong>AT</strong>+CDIS?Test command<strong>AT</strong>+CDIS=?Possible response(s)OKorCME ERROR: +CDIS: [[,...]]OK+CDIS: [,[,...]]OKDefined values is a string type parameter using character set specified by command +CSCS. is a integer type parameter giving the maximum length of corresponding parameter.7.10. Indicator control +CINDDescriptionThis set command is used to set the values of MT indicators. value 0 means that the indicatoris off, 1 means that the indicator is on, 2 is more substantial than 1, and so on. The proprietarycommand +XCIND configure the supported indicators; the default configuration of +XCIND enablesthe support of all indicators listed below. The read command returns the status of MT indicators.The test command returns pairs, where string value is a maximum 16 character descriptionof the indicator and compound value is the allowed value for the indicator. If Bluetooth communicationis supported, the length of the displayed string may be reduced to 127 bytes by using theconfiguration command +XCIND.SyntaxCommand syntax: <strong>AT</strong>+CINDBecause all possible supported parameters of the set syntax can not be overwritten, the setting willbe ignored and the <strong>AT</strong>C sends the corresponding final result code OK to TE.CommandPossible response(s)<strong>AT</strong>+CIND=[[,[,...]]] OKorCME ERROR: Read command+CIND: [,[,...]]<strong>AT</strong>+CIND?OKTest command+CIND:(“battchg”,(0-5)),(“signal”,(0-5)),(“service”,(0-<strong>AT</strong>+CIND=?1)),(“sounder”,(0-1)),(“message”,(0-1)),(“call”,(0-1)),(“roam”,(0-1)),(“smsfull”,(0-(2) or proprietary, seenote)),(“gprs”,(0-1)),(“callsetup”,(0-3)),(“callheld”,(0-2))OKDefined values: integer type value, which shall be in range of corresponding values reserved by the norm and their ranges; it may have the values:- “battchg” battery charge level (0-5); see also +CBC for details;- “signal” signal quality (0-5); see also +CSQ for details;- “service” service availability (0-1);Confidential DAVISCOMMS (S) PTE LTD 56 /136

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!