12.07.2015 Views

Busch-Watchdog presence detector Type: 6131-74-101

Busch-Watchdog presence detector Type: 6131-74-101

Busch-Watchdog presence detector Type: 6131-74-101

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ABB i-bus ® EIB<strong>Busch</strong>-<strong>Watchdog</strong> <strong>presence</strong> <strong>detector</strong><strong>Type</strong>: <strong>6131</strong>-<strong>74</strong>-<strong>101</strong>HVACThe <strong>presence</strong> <strong>detector</strong> can activate aheating or ventilation controller with itsobject “Movement HVAC”. The objectsends telegrams without dependenceon the brightness value.The ON delay is the period which theHVAC channel needs until it detects amovement. This period is automaticallyset by default by the <strong>presence</strong> <strong>detector</strong>.It can however also be preselected. Todo so, the parameter “Switch ON isadjustable” must be set to “by ETS”.The time is composed of a base and afactor in the same way as the recoverytime.If the switch ON behaviour is set withthe HVAC potentiometer, the followingshould be noted:– If an OFF delay between 1 and 10min is assigned with thepotentiometer, the ON delay is set at30 s. This setting can for exampleswitch on an extractor fan in the WC.– If the OFF delay is set at longer than10 min, the ON time is based on thefrequency of detection of movement.In a standard office, the heatingsystem is only switched on when theemployee stays there for a longerperiod. In a conference room whichis seldom used, the heating is notactivated when someone enters theroom briefly and then leaves againafter a short period.The object “Movement HVAC” cantrigger a telegram after detection of amovement and after an adjustablerecovery time. With the parameter“<strong>Type</strong> of movement object”, it ispossible to set whether 1 bit switchingtelegrams or 1 byte value telegramsare triggered. The switching telegramscan also be sent cyclically in the sameway as the movement channels.Bus voltage recoveryThe states of the communicationobjects “Movement channel ... / Telegr.switch” adopt a defined status on busvoltage recovery. The states ofchannels 1 and 2 can be definedseparately. There are thus nounnecessary switching operations onbus voltage recovery.Defined states can also be selected forthe objects “Brightness dependentswitching channel ...”. The parametersare only visible if the objects havepreviously been enabled.2 - 78 May 2002

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!