ABB i-bus® EIB Room thermostat solo®, FM Type: 6124-xx

ABB i-bus® EIB Room thermostat solo®, FM Type: 6124-xx

ABB i-bus® EIB Room thermostat solo®, FM Type: 6124-xx

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ABB</strong> i-bus ® <strong>EIB</strong><strong>Room</strong> <strong>thermostat</strong> solo ® , <strong>FM</strong><strong>Type</strong>: <strong>6124</strong>-<strong>xx</strong>ParametersThe default setting for the valuesis printed in bold type.Heating:– Output of control value continuous / switchingFor switching control value:– Control type Two-step control / PWM controlOnly for two-step control:– Hysteresis 0.3 K / 0.5 K / 0.7 K / 1.0 K / 1.5 K / 2 K– Reduction of hysteresis inactive0.2 K/min…0.029 K/min– Cyclic time for automatic inactivesending…every 20 minevery 30 minevery 60 min– Mode of control output normal / invertedOnly for PWM control:– Control parameter by installation typemore detailedOnly if “by installation type” is selected:– <strong>Type</strong> of heating Warm water heating (1.5 K/100 min)Electrical heating (1.5 K/50 min)Floor heating (4 K/200 min)Only if “more detailed” is selected:– Proportional range 1 K / 1.5 K / … / 10 K– Readjust time in min. 0 min / 10 min / … / 100 min / 120 min /… / 240 min– Cyclic time of the switching 3 min / 5 min / 10 min / 15 min /control value20 min / 30 min– PWM cycle is 0% up to an 0 % / 5 % / 10 % / … / 30 %output value– PWM cycle is 100% down to 70 % / … / 90 % / 95 % / 100 %an output value– Mode of control output normal / invertedFor continous control value:– Control parameter by installation typemore detailedOnly if “by installation type” is selected:– <strong>Type</strong> of heating Warm water heating (1.5 K/100 min)Electrical heating (1.5 K/50 min)Floor heating (4 K/200 min)Only if “more detailed” is selected:– Proportional range 1 K / 1.5 K / … / 10 K– Readjust time in min. 0 min / 10 min / … / 100 min / 120 min /… / 240 min– Minimum control value 0 % / 5 % / 10 % / … / 30 %– Maximum control value 70 % / … / 90 % / 95 % / 100 %– Cyclic time for automatic sending inactiveof control output…every 20 minevery 30 minevery 60 min– Mode of control output normal / invertedAdditional heating:– Difference between basic heating 1 K / 2 K / 3 Kand additional heating– Hysteresis (one-sided) 0.15 K / … / 1.0 K– Cyclic time for automatic sending no cyclical sending / every 3 min /of control value… / every 15 min / … / every 60 min– <strong>Type</strong> of control value semi-continuous (1 byte: 0% or 100%)switching (1 bit)– Mode of control output normal / invertedMarch 2003 2 - 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!