12.07.2015 Views

DESIGN AND DEVELOPMENT OF MEDICAL ELECTRONIC ...

DESIGN AND DEVELOPMENT OF MEDICAL ELECTRONIC ...

DESIGN AND DEVELOPMENT OF MEDICAL ELECTRONIC ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

10 BIOPOTENTIAL AMPLIFIERSFigure 1.8 Printed circuit board for a high-input-impedance buffer array. The output of each channelis used to drive guard rings which form low-impedance isopotential barriers that shield all inputpaths from leakage currents.laid out and constructed with care to take advantage of the op-amp’s high input impedance.As shown in the PCB layout of Figure 1.8, the output of each channel is used to drive guardrings that form low-impedance isopotential barriers that shield all input paths from leakagecurrents.The selection of op-amps from the TLC27 family has the additional advantage thatelectrostatic display (ESD) protection circuits that may degrade high input impedance areunnecessary because LinCMOS chips have internal safeguards against high-voltage staticcharges. Applications requiring ultrahigh input impedances (on the order of 10 10 Ω) necessitateadditional precautions to minimize stray leakage. These precautions include maintainingall surfaces of the printed circuit board (PCB), connectors, and components free ofcontaminants, such as smoke particles, dust, and humidity. Residue-free electronic-gradeaerosols can be used effectively to dust off particles from surfaces. Humidity must beleached out from the relatively hygroscopic PCB material by drying the circuit board in alow-pressure oven at 40C for 24 hours and storing in sealed containers with dry silica gel.If even higher input impedances are required, approaching the maximal input impedanceof the TLC24L4, you may consider using Teflon 2 PCB material instead of the more commonglass–epoxy type.Typical applications for this circuit include active medallions, which are electrode connectorblocks mounted in close proximity to the subject or preparation. The low inputnoise (68 nV/ Hz) and high bandwidth (dc—10 kHz) make it suitable for a broad range ofapplications. For example, 32 standard Ag/AgCl electroencephalography (EEG) electrodesfor a brain activity mapper could be connected to such a medallion placed on a headcap.Figure 1.9 shows another application for the circuit as an active electrode array in electromyography(EMG). Here eight arrays were used to pick up muscle signals from 256points. Connectors J1 in each of the circuits were made of L-shaped gold-plated pins that areused as electrodes to form an array with a spatial sampling period of 2.54 mm (given by thepitch of a standard connector with 0.1-in. pin center to center). The outputs of the op-ampbuffers can then carry signals to the main biopotential signal amplifiers and signal processors2 Teflon is a trademark of the DuPont Corporation.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!