Extended <strong>Functi</strong>onsAutomatic restart (vector, infeed)Commissioning1. Activating the function for vector and infeed drive object– Automatic restart: set mode (p1210).– Flying restart: Activate function (p1200).2. Set starting attempts (p1211).3. Set waiting times (p1212, p1213).4. Check function.Important parameters (refer to the List Manual) r0863 CO/BO: Drive coupling status word/control word p1207 BI: Automatic restart – connection to the following DO p1208 BI: Automatic restart – infeed fault p1210 Automatic restart, mode p1211 Automatic restart, attempts to start p1212 Automatic restart, delay time start attempts p1213 Automatic restart, waiting time increment© Siemens AG 2006 All Rights Reserved<strong>SINAMICS</strong> <strong>S120</strong> <strong>Functi</strong>on Manual, 03/2006 Edition4-199