Extended <strong>Functi</strong>onsMotor changeover4.10 Motor changeover4.10.1 DescriptionThe motor changeover is used in the following cases, for example: Changing-over between different motors and encoders Switching over different windings in a motor (e.g. star-delta switchover) Adapting the motor dataIf several motors are operated alternately on a Motor Module, a matching numberof drive data sets must be created (also refer to Section 5.2).NoteTo switch to rotating motor, the “flying restart” function must be activated (p1200).NoticeWhen changing over the drive data set between several motors that physicallyexist with integrated holding brakes, it is not permissible that the internal brakecontrol is used.4.10.2 IntegrationThe motor switchover function is integrated in the system as follows.<strong>Functi</strong>on diagram overview (refer to the List Manual) 8565 Drive data set (DDS) 8570 Encoder data set (EDS) 8575 Motor data set (MDS)© Siemens AG 2006 All Rights Reserved<strong>SINAMICS</strong> <strong>S120</strong> <strong>Functi</strong>on Manual, 03/2006 Edition4-207