12.07.2015 Views

Hand-held Pendant Stations - EUCHNER GmbH + Co. KG

Hand-held Pendant Stations - EUCHNER GmbH + Co. KG

Hand-held Pendant Stations - EUCHNER GmbH + Co. KG

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Hand</strong>-<strong>held</strong> <strong>Pendant</strong> <strong>Stations</strong><strong>Hand</strong>-<strong>held</strong> pendant station HBLS-072725ff<strong>Hand</strong>wheel 100 pulsesffTamper-proof emergency stop deviceaccording to EN ISO 13850,dual-channelff2 pushbuttons, 2-stage, e.g. forenabling functionffKeypad with 12 illuminated keysffKeypad can be designed as requiredusing slide-in filmff2 selector switchesffLCD display (text mode)ffRS422 interface, 3964R protocolDimension drawing114S1Display, 8 lines,15 characters/lineHanging clip77120Mounting magnet252S2/S3Pushbutton2-stage,left/rightA1NotesffHolder HBL for hand-<strong>held</strong> pendant stations:see accessories page 58ffAssociated flange connector, 23-pin:see connection components page 51ffActiveX module available for integrating theuser’s applications (for MS Windows ® -baseduser programs with ActiveX support)Cable length3,500 mmPlug connector23-pinTechnical dataParameter Value UnitHousing HBLMaterialPlastic<strong>Co</strong>lor Blue-gray RAL 7031Operating temperature 0 ... +50 °CDegree of protection according to EN 60529 IP 65<strong>Co</strong>nnectionCable 3.5 m, 23-pin plugWeight 2.2 kgEmergency stop deviceStandard EN ISO 13850Switching elements2 NC contactsUtilization category according to IEC 60947-5-1DC-13 U e 24 V I e 2.75 A<strong>Hand</strong>wheel HKDPulses per revolution 100Output circuitRS 422 AOutput signals see page 67Pushbutton ZSG, 2-stage, e.g. for enabling functionSwitching elements2, one NO contact eachUtilization category according to IEC 60947-5-1AC-15 U e 24 V I e 4 ADC-13 U e 24 V I e 3 AInterfaceType RS 422Data format8 data bits , even parity, 1 or 2 stop bitsTransfer speed 9600 or 19200 (setting using DIL switches) baudTransfer protocol3964 RElectrical connectionPower supply 24 ±20% V DCOperating current, max. 200 mA26Subject to technical modifications; no responsibility is accepted for the accuracy of this information. Devices supplied may vary slightly from the illustration in the catalog.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!