13.07.2015 Views

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

22.4<strong>Metering</strong> <strong>Devices</strong>, <strong>Protective</strong> <strong>Relays</strong>, <strong>Software</strong> <strong>and</strong> Connectivity<strong>Protective</strong> <strong>Relays</strong>222222222222222222222222222222222222222222222222222222222222Feeder Protection FP-4000ContentsDescriptionPageProduct Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . 282FP-6000 Feeder Protection . . . . . . . . . . . . . . . . . . . . . . . . . 286FP-5000 Feeder Protection . . . . . . . . . . . . . . . . . . . . . . . . . 296FP-4000 Feeder ProtectionFeatures, Benefits <strong>and</strong> Functions . . . . . . . . . . . . . . . . . . 305St<strong>and</strong>ards <strong>and</strong> Certifications . . . . . . . . . . . . . . . . . . . . . . 307Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . 307Technical Data <strong>and</strong> Specifications . . . . . . . . . . . . . . . . . . 308Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311MP-3000 Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . 312MP-4000 Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . 322MD-3000 Motor/Generator Differential Relay . . . . . . . . . . . 328Digitrip 3000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331VR-300 Multifunctional Voltage Relay . . . . . . . . . . . . . . . . . 341DP-300 Current Differential Protection Relay. . . . . . . . . . . . 345EDR-3000 Feeder Protection . . . . . . . . . . . . . . . . . . . . . . . . 350ETR-4000 Transformer Protection Relay . . . . . . . . . . . . . . . 361Ground Fault Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374Universal RTD Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 378IQ 125 Volt DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . 382FP-4000 Feeder ProtectionProduct Description● Microprocessor-basedprotection with monitoring<strong>and</strong> control for mediumvoltage main <strong>and</strong> feederapplications● Current, voltage, frequency<strong>and</strong> power protection forelectric power distributionsystems● Complete metering ofvoltage, currents, power,energy, minimum/maximum <strong>and</strong> dem<strong>and</strong>functions● Programmable logic controlfunctions for main-tie-maintransfer schemes● Trip logs, event logs <strong>and</strong>waveform capture forbetter fault analysis <strong>and</strong>system restoration● Data logger to provideenergy usage profiles forbetter planning, utilization<strong>and</strong> energy usage● Compact, drawout casedesign●Meets ANSI, CE <strong>and</strong> CSAst<strong>and</strong>ards●Multiple settings groups●ANSI, IEC <strong>and</strong> thermalprotection curves forgreater flexibilityApplication DescriptionEaton’s FP-4000 FeederProtection relay providescomplete three-phase <strong>and</strong>ground overcurrent <strong>and</strong>voltage protection plusmetering in a single, compactdrawout case. It may be usedas primary protection onfeeders, mains <strong>and</strong> tie circuitbreaker applications, <strong>and</strong>as backup protection fortransformers, high voltagelines <strong>and</strong> differentialprotection. The relay ismost commonly used onmedium voltage switchgearapplications.The FP-4000 takes fulladvantage of its microprocessortechnologyproviding the user newfreedoms <strong>and</strong> a wealth ofata-gathering features. Therelay performs self-checkingf all major hardware <strong>and</strong>firmware protection elementsto ensure their operation in theevent of a system orcomponent electrical failureor fault. Protection functionsare well suited for main <strong>and</strong>distribution feeder circuitapplications. Programmablelogic control functions makethe FP-4000 relay <strong>ideal</strong>ly suitedfor main-tie-main <strong>and</strong> main1/main 2 transfer schemes.The Zone-Interlocking featurecan be utilized for busprotection instead of anexpensive <strong>and</strong> complicatedbus differential (87B)scheme. The FP-4000 worksdirectly with Eaton’s Digitrip3000 <strong>and</strong> Digitrip MV relays.New breaker failure logicprovides faster remotebackup clearing times forstuck breaker operation.The multiple settings groupscan be utilized for arcflash mitigation when analternative setting group,set to have instantaneouselements only is activatedusing a selector switch <strong>and</strong>the programmable I/O inthe FP-4000.The FP-4000 provides trip<strong>and</strong> close circuit monitoring<strong>and</strong> alarming features. Itcontinually monitors thecomplete trip <strong>and</strong> closecircuits for continuity <strong>and</strong>readiness to trip. Open <strong>and</strong>close pushbuttons areconveniently located on thefront of the relay for localbreaker operation.Loss-of-vacuum monitoringis activated when the breakeris open. Residual current ismonitored <strong>and</strong> alarmed ifdetected.When an electrical faultor disturbance occurs, theFP-4000 begins to store thefollowing in non-volatilememory:●●●Voltage <strong>and</strong> currentsampled dataCalculated valuesStatus of internalprotection functions, logic,contact inputs <strong>and</strong> outputsRetrieval <strong>and</strong> viewing of thedata is easy, aiding in thequick analysis <strong>and</strong> restorationof your electric powersystem.304 Volume 3—Power Distribution <strong>and</strong> Control Assemblies CA08100004E—December 2010 www.eaton.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!