13.07.2015 Views

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Metering</strong> <strong>Devices</strong>, <strong>Protective</strong> <strong>Relays</strong>, <strong>Software</strong> <strong>and</strong> Connectivity<strong>Protective</strong> <strong>Relays</strong>22.4Catalog Number SelectionThe catalog numberidentification chart definesthe electrical characteristics<strong>and</strong> operation featuresincluded in the EDR-3000. Forexample, if the catalog numberwere EDR3000-A0BA1,the device would havethe following:Relay Removable TerminalsHardware Option 1A = 4 digital inputs, 4 outputs,removable terminalsB = 8 digital inputs, 6 outputs, removableterminals, trip coil monitor C = 4 digital inputs, 4 outputs, removableterminals, zone interlocking <strong>and</strong> IRIG-B Relay Fixed Terminals Hardware Option 1 E = 4 digital inputs,4 outputs, fixed terminalsF = 4 digital inputs,4 outputs, fixed terminals,zone interlocking<strong>and</strong> IRIG-BEDR-3000(A)–Four digital inputs,four output relays(0)–Phase current 5A/1A,Ground Current 5A/1A,Power supply: 19–300 Vdc,40–250 VacHardware Option 20 = Phase current 5A/1A, groundcurrent 5A/1A, power supplyrange: 19–300 Vdc,40–250 VacHardware Option 2 0 = Phase current 1A, ground current 1A, power supplyrange: 19–72 Vdc1 = Phase current 5A, ground current 5A, power supplyrange: 19–72 Vdc2 = Phase current 1A, sensitive groundcurrent 0.1A, power supply range:19–72 Vdc3 = Phase current 5A, sensitive groundcurrent 0.5 A, power supply range:19–72 Vdc4 = Phase current 1A, ground current 1A, power supplyrange: 85–300 Vdc,85–250 Vac5 = Phase current 5 A, ground current 5A, power supplyrange: 85–300 Vdc,85–250 Vac6 = Phase current 1A, sensitive groundcurrent 0.1 A, power supply range:85–300 Vdc, 85–250 Vac7 = Phase current 5A, sensitive groundcurrent 0.5A, power supply range:85–300 Vdc, 85–250 VacEDR3000 A 0 B A 1(B)–Modbus-RTU (RS-485)(A)–Without conformalcoating(1)–Projection panel mountCommunication OptionsB = Modbus-RTU(RS-485)C = Modbus-TCP (RJ-45)EDR3000 E 0 B A 1CommunicationOptionsB = Modbus-RTU(RS-485)C = Modbus-TCP (RJ-45)Notes Consult factory for the availability of eight digital inputs, six outputs, trip coil monitor, zone interlocking, IRIG-B <strong>and</strong> Modbus-TCP.Consult factory for the availability of fixed terminals.Conformal CoatingOptionsA = NoneB = Conformal coatedcircuit boardsConformal CoatingOptionsA = NoneB = Conformal coatedcircuit boardsMounting Options0 = St<strong>and</strong>ard mount1 = Projection panel mountMounting Options0 = St<strong>and</strong>ard mount1 = Projection panel mount222222222222222222222222222222222222222222222222222222222222Volume 3—Power Distribution <strong>and</strong> Control Assemblies CA08100004E—December 2010 www.eaton.com 353

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!