13.07.2015 Views

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

22.3<strong>Metering</strong> <strong>Devices</strong>, <strong>Protective</strong> <strong>Relays</strong>, <strong>Software</strong> <strong>and</strong> Connectivity<strong>Metering</strong> <strong>Devices</strong>22222222222222222222222222222222222222222222222222222222FeaturesThe IQ Multipoint EnergySubmeter II offers low-costmetering of kW <strong>and</strong> kWh formultiple tenants of residential<strong>and</strong> commercial officebuildings for one- to threephasevoltage loads notexceeding 347/600 volts.The IQ Multipoint EnergySubmeter II contains INCOMnetworking to chain togethermultiple meters in locationsthroughout the facility. Seeabove for a typical apartmentbuilding layout.●Multipoint electricalenergy metering●Built-in communicationinterface● Flexible meteringconfiguration● Monitors single-phase <strong>and</strong>three-phase loads from120 Vac to 600 Vac in threevoltage ranges● Monitors power in watts<strong>and</strong> energy in watthoursfor up to 16 CurrentSensors● Very low profile design,less than 1.50 inches(38.1 mm) in height● Energy values stored innon-volatile memory● Stores extensive energyprofile data for eachmetering point. Canbe used to identifycoincidental peakdem<strong>and</strong> contribution● Space-saving stackingdesign allows two units tobe mounted together● Supports Time-of-Useenergy monitoring● Dem<strong>and</strong> interval adjustablefrom 5 to 60 minutes● Measures bus voltage● Front panel LEDs providestatus of unit <strong>and</strong>communication activity● Meets rigid ANSI C12.1<strong>and</strong> IEC 61036 accuracyspecifications for revenuemeters● Can be directly mounted ina UL-approved panelboardor switchboardCommunication CapabilitiesWith the IQ Multipoint EnergySubmeter II’s built-incommunication capabilities,remote meter reading <strong>and</strong>monitoring functions can beintegrated into both new <strong>and</strong>retrofit applications.Eaton’s INCOMcommunications is built intoeach IQ Multipoint EnergySubmeter II for chainingthem together on a robust,field-proven, communicationsarchitecture. INCOM can beused to communicate to thecomplete line of Eaton’smetering products <strong>and</strong> isalso useful for thoseprojects requiring localcommunications to PowerXpert Power Managementsystem.In addition Page 252 listsseveral Gateway products toenable communications toRS-232 Ethernet or RS-485with Modbus protocol.<strong>Software</strong> Compatibility● The IQ Multipoint EnergySubmeter II is fullycompatible with Eaton’sPowerNet softwareplatform including the E-Billcost allocation software● The IQ Multipoint EnergySubmeter II can be utilizedas part of an electricalenergy monitoring <strong>and</strong>billing system● The IQ Multipoint EnergySubmeter II can beremotely monitored viaEaton’s FetchIT softwarepackage● The IQ Multipoint EnergySubmeter II is compatiblewith third-party softwareplatforms <strong>and</strong> interfacedevicesConfiguration●The IQ Multipoint EnergySubmeter II is fullyconfigurable using PowerXpert or free PowerPortconfiguration software●PowerPort can bedownloaded free fromeither the Internet or theEaton Intranet● Each IQ Multipoint EnergySubmeter II can beconfigured for up to 16metering points in anycombination of singlephase<strong>and</strong> three-phasemetering points●PowerPort is used toassign Current Sensorsto metering points● Either PowerPort or PowerXpert can be used toconfigure the built-in datalogs for energy profiling● Both Power Xpert <strong>and</strong>PowerPort can be used toset up the Time-of-Useenergy registers <strong>and</strong> theAutomatic Meter ReadingscheduleWiring● The Current Sensor cableis rated 600 volts <strong>and</strong> isrecognized by UL asClass 1 wiring● IMPCABLE used forINCOM communicationbetween devices is rated600 volts <strong>and</strong> is recognizedby UL as Class 1 wiring● Consult TD17513 WiringSpecification Base Rulesfor detailed informationon proper installation <strong>and</strong>termination of INCOMcommunicationsnetwork cableEasy to Install●Approved by UL formounting insidepanelboards <strong>and</strong>switchboards●Stacking design allows twounits to be mounted in apanelboard using less that8 inches (203.2 mm) ofvertical space● For retrofit applications,the IQ Multipoint EnergySubmeter II can bemounted in an externalauxiliary enclosure●Quick connect terminalsfor Current Sensors,INCOM communications<strong>and</strong> bus voltages makewiring the unit quick <strong>and</strong>easyReduced Equipment SpaceThe IQ Multipoint EnergySubmeter II consumes 80%less wall space compared toglass bulb meters that must beindividually or group mountedindependent of the loadcenteror panelboard. By installing themeter in the loadcenter <strong>and</strong>providing Current Sensorsto each load within thepanelboard, less real estate isoccupied, not only in theground floor, but at individualtenant floor spaces. A typicalintegrated distribution <strong>and</strong>metering solution using the IQMultipoint Energy Submeter IIuses 45% less wall space thanseparately mountedsubmeters.2222250 Volume 3—Power Distribution <strong>and</strong> Control Assemblies CA08100004E—December 2010 www.eaton.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!