13.07.2015 Views

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

22.3<strong>Metering</strong> <strong>Devices</strong>, <strong>Protective</strong> <strong>Relays</strong>, <strong>Software</strong> <strong>and</strong> Connectivity<strong>Metering</strong> <strong>Devices</strong>222222222222222222222222222222222222222222222222222222222222Technical Data <strong>and</strong> SpecificationsAccuracy●Maintained from 10–250%of CT primary ratingCurrent Inputs (Each Channel)●Nominal full scale current:5 amperes AC●Current range for ratedaccuracy: 0–15 amperes AC●Overload withst<strong>and</strong>:15 amperes ac continuous300 amperes AC 1 second● Burden: 0.003 VAModel 4100 Input <strong>and</strong> OutputControl Power InputDisplayed ValuesNoteAll accuracy is measured as a percentage of full scale.Voltage Inputs (Each Channel)●Voltage range (nominal):90–600 Vac●Nominal full scale voltage:120–600 Vac●Overload withst<strong>and</strong>:660 Vac continuous 4 kV1.2/50 µs●Burden: three-phasepower module 10 VAFusesSupplied with three-phasepower module only. 3/4ampere, 600 volt bus typeKTK-R-3/4 (three required).Contact Rating (Model 4100)● 10 amperes at 120/240 Vac(resistive)● 10 amperes at 30 Vdc(resistive)Model Input Output4000 0 04100 1 digital (dry contact) 3 relaysCompatible with theFollowing Systems●Three-phase, three-wire●Three-phase, four-wireDescription Separate Source Self Powered DC SourceInput range, ACFrequency rangeInput range, DCBurden110–240 Vac ±10%45–66 Hz110–250 Vac ±10%10 VA110–600 Vac ±10%45–66 HzN/A10 VARatings●Application to 500 kV,no PTs to 600 volts●CT ratios selectable from5:5 A to 12800: 5A● St<strong>and</strong>ard 120/600 Vac linethree-phase power supplymodule. Two separatesource power supplymodules available. Onemodule from 110– 240 Vac<strong>and</strong> 110–250 Vdc; the othermodule 24–48 Vdc onlyN/AN/A24–48 Vdc ±20%10 VADescriptionDisplayed Through Eaton’sPowerNet SystemLocal DisplayAC amperes, phases A, B, C ± 0.3% ± 0.3% ± 1 digitAC voltage, phase A-B, B-C, C-A ± 0.3% ± 0.3% ± 1 digitPhase A-N, B-N, C-N ± 0.3% ± 0.3% ± 1 digitWatts ± 0.6% ± 0.6% ± 1 digitVars ± 0.6% ± 0.6% ± 1 digitVA ± 0.6% ± 0.6% ± 1 digitWatt-hours ± 0.6% ± 0.6% ± 1 digitVAR-hours ± 0.6% ± 0.6% ± 1 digitVA-hours ± 0.6% ± 0.6% ± 1 digitPower factor ± 1% ± 1%Frequency ± 0.1 Hz ± 0.1 Hz% THD Through 31st harmonic Through 31st harmonic238 Volume 3—Power Distribution <strong>and</strong> Control Assemblies CA08100004E—December 2010 www.eaton.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!