13.07.2015 Views

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

Metering Devices, Protective Relays, Software and ... - Mercado-ideal

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

22.4<strong>Metering</strong> <strong>Devices</strong>, <strong>Protective</strong> <strong>Relays</strong>, <strong>Software</strong> <strong>and</strong> Connectivity<strong>Protective</strong> <strong>Relays</strong>222222222222222222222222222222222222222222222222222222222222EDR-3000ContentsDescriptionPageProduct Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . 282FP-6000 Feeder Protection . . . . . . . . . . . . . . . . . . . . . . . . . 286FP-5000 Feeder Protection . . . . . . . . . . . . . . . . . . . . . . . . . 296FP-4000 Feeder Protection . . . . . . . . . . . . . . . . . . . . . . . . . 304MP-3000 Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . 312MP-4000 Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . 322MD-3000 Motor/Generator Differential Relay . . . . . . . . . . . 328Digitrip 3000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331VR-300 Multifunctional Voltage Relay . . . . . . . . . . . . . . . . . 341DP-300 Current Differential Protection Relay. . . . . . . . . . . . 345EDR-3000 Feeder ProtectionFeatures, Benefits <strong>and</strong> Functions . . . . . . . . . . . . . . . . . . 352St<strong>and</strong>ards <strong>and</strong> Certifications . . . . . . . . . . . . . . . . . . . . . . 352Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . 353Technical Data <strong>and</strong> Specifications . . . . . . . . . . . . . . . . . . 354Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359ETR-4000 Transformer Protection Relay . . . . . . . . . . . . . . . 361Ground Fault Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374Universal RTD Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 378IQ 125 Volt DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . 382EDR-3000 Feeder ProtectionProduct DescriptionThe EDR-3000 <strong>Protective</strong>Relay is a multifunction,microprocessor-basedovercurrent relay designedfor both ANSI <strong>and</strong> IECapplications. It is a panelmounted,self-contained unitthat operates from either ACor DC control power. TheEDR-3000 design providestrue rms <strong>and</strong> fundamentalsensing of each phase <strong>and</strong>ground current. Only one unitis required for each threephasecircuit.Current monitoring <strong>and</strong>operator selectable protectivefunctions are integral to eachrelay. The EDR-3000 relayoperates from the 5A or 1Asecondary output of st<strong>and</strong>ardcurrent transformers. Currenttransformer ratio informationis quickly programmed intothe unit via settings. Thisenables the relay to displaymetered current in primaryamperes, secondary amperesor per unit values. The EDR-3000 features a user-friendlyoperations panel to monitor<strong>and</strong> program the relay.Operating parameters <strong>and</strong>troubleshooting informationare displayed in the 128 x 64LCD. In addition, all data <strong>and</strong>information can becommunicated to a hostcomputer equippedwith PowerPort-E.A “Communication Trip” <strong>and</strong>“Communication Close”control comm<strong>and</strong> can also beinitiated by a host computerwith an authorized accesscode for remote breakeroperation.Application DescriptionThe EDR-3000microprocessor-based relayprovides reliable three-phase<strong>and</strong> ground overcurrentprotection for all voltagelevels. It can be used forany application whereinstantaneous <strong>and</strong>/or timeovercurrent protection isrequired. It is mostcommonly used as primaryfeeder circuit protection,shown below.Primary Feeder CircuitProtection50 5150G 51GCB52 EDR-3000LoadThe EDR-3000 may beapplied as the transformerprimary protection or asbackup to the differentialprotection, see below.Transformer OvercurrentProtectionCB50 5150G51GEDR-3000The EDR-3000 may beconnected to the secondaryside of a delta-wye groundedtransformer with the groundelement connected to aseparate CT in the neutralconnection of thetransformer. With thisconnection, a lower CTratio <strong>and</strong> a pickup settingcan be used to providemore sensitive ground faultprotection especially forresistance groundedsystems, shown below.Transformer SecondaryProtection with Neutral CTConnectionCB50G51G50 51EDR-3000ResistorThe EDR-3000 relay hasspecial provisions forconnection in a ZoneInterlocking scheme that canbe used for bus protectionor to improve protectioncoordination in a tight or closesystem. Zone Interlockingis described in followingsections. In addition theEDR-3000 has multiplesetting groups that can beused to reduce arc flashhazard with instantaneouselements.Residual Ground ConnectionCB-52abc25836950/5150N/51NGND 12 11EDR-3000350 Volume 3—Power Distribution <strong>and</strong> Control Assemblies CA08100004E—December 2010 www.eaton.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!