13.07.2015 Views

Tracer AV Installation Manual - Rice Lake Weighing Systems

Tracer AV Installation Manual - Rice Lake Weighing Systems

Tracer AV Installation Manual - Rice Lake Weighing Systems

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CONFIG MenuMOTBAN 1numberOVRLOASMPRATDIGFL1DIGFL2DIGFL3Parameter Choices DescriptionDFSENSDFTHRHTAREFNFS+2%FS+1DFS+9DFS15HZ30HZ60HZ7.5HZ81632641248OUT16OUT32OUT64OUT128OUT2OUT4OUTNONE2DD5DD10DD20DD50DD100DD200DD250DDBOTHNOTAREPBTAREKEYEDSets the level, in display divisions, at which scale motion is detected. If motion is notdetected for 1 second or more, the standstill symbol lights. Some operations, includingprint, tare, and zero, require the scale to be at standstill. Maximum legal value variesdepending on local regulations.If this parameter is set to 0, the standstill annunciator will be set continuously on, andoperations including zero, print, and tare will be performed regardless of scale motion. If 0is selected, ZTRKBND must also be set to 0.Overload. Determines the point at which the display blanks and an out-of-range errormessage is displayed. Maximum legal value varies depending on local regulations.Sample rate. Selects measurement rate, in samples per second, of the analog-to-digitalconverter. Lower sample rate values provide greater signal noise immunity.Digital filtering. Selects the digital filtering rate used to reduce the effects of mechanicalvibration from the immediate area of the scale.Choices indicate the number of A/D conversions that are averaged to obtain thedisplayed reading. A higher number gives a more accurate display by minimizing theeffect of a few noisy readings, but slows down the settling rate of the indicator. SeeSection 6.6 on page 37 for more information on digital filtering.Digital filter cutout sensitivity. Specifies the number of consecutive readings that must falloutside the filter threshold (DFTHRH parameter) before digital filtering is suspended. IfNONE is selected, the filter is always enabled.Digital filter cutout threshold. Specifies the filter threshold, in display divisions. When aspecified number of consecutive scale readings (DFSENS parameter) fall outside of thisthreshold, digital filtering is suspended. If NONE is selected, the filter is always enabled.Tare function. Enables or disables push-button and keyed tares. Possible values are:BOTH:Both push-button and keyed tares are enabledNOTARE:No tare allowed (gross mode only)PBTARE:Push-button tares enabledKEYED:Keyed tare enabledTable 3-4. Configuration Menu Parameters (Continued)14 <strong>Tracer</strong> <strong>AV</strong> <strong>Installation</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!