Status indicators:StatusdisplayMeaningStatusdisplayMeaning0 Switch 1 TW - Delay2 Temperature monitoring 3 Pressure monitoring4 Delay 5 TA - Delay6 Troubleshooting 7 Troubleshooting confirmedwith key8 - 13 ZeroingSetting values and their meanings:Description Abbr. Range Factorysetting )*Pressure limit dp_soll 4 Pa - 20 Pa 4 PaUp Time Tw 1 min - 30 min 1 minDelay for switching off whilebelow the boundaryWaiting time betweenshutdown and re-checkingTemperature for activation ofthe pressure monitoringsystemTv 1 sec - 30 sec 20 secTa 1 min - 30 min 15 minTemperature 20°C - 100°C 50 °C) * Value in delivery stateDuring commissioning, the set values are to be checked and in thefollowing table entered. The <strong>USA</strong> must be tested with the enteredvalues and put into operation are. With these changes are to taketo the table.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 17August 2013