TECHNICAL DATAThe <strong>USA</strong> has been tested by TÜV South Germany GmbHGeneral building approval by DIBt; approval number Z-85.1-8.Test Report C 1207-00/04 vom 31.03.2004Dimensions 170 x 170 x 60 (b x h x t)ProtectionOperating VoltagePressure Sensor RangeFuseFuse Switch OutputIP20 / DIN 40050 CE230 V +10% -15% / 50Hz / 3VA-8.5 Pa - 50 PaT 160 mAT2AAmbient Temperature 10 °C - 50 °CTemperature SensorMeasuring Range PT100 -40 to 600 °CPT1000 exact degree of DIN EN60751Maximum Temperature Loads PT1000 Metal Braid –50 to 350°CMeasuring Hose 260°CTemperature Resistance Table for PT1000<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 25August 2013