e exempted when the total design gives the same protection. <strong>The</strong> areasurrounding a ground level structure shall be graded in a manner that willprevent surface water from standing within 50 feet of it. Steel storagetanks shall not be located below the ground surface.7.0.4. Roofs on Unpressurized Finished <strong>Water</strong> Storage StructuresAll unpressurized finished water storage structures shall have suitablewatertight roofs that prevent entrance of birds, animals, insects, and excessivedust. <strong>The</strong> roof shall be well drained. Downspouts shall not enter or passthrough the storage structure.7.0.5. Protection of Finished <strong>Water</strong> Storage StructuresAll finished water storage structures shall be protected from trespassing,vandalism, and sabotage. Protection shall include at least the following:a. Locked hatches and other access openings;b. Physical barriers to entrance of ladders; andc. Security fencing with locked gates.See also section 2.5, Security Measures.7.0.6. Vents on Unpressurized Finished <strong>Water</strong> Storage StructuresAll unpressurized finished water storage structures shall be vented.Overflows shall not be considered vents. Open construction between thesidewall and roof is not permissible. Vents shall meet the following criteria:a. Vents shall be sized with sufficient capacity to pass air so that themaximum flow of water entering or leaving the tank will not causeexcessive pressure or vacuum. Maximum flow of water leaving the tankshall include the rate produced by a catastrophic large main failure nearthe tank. Resistance of air flow caused by the vent screens shall beconsidered in sizing the vents;b. Vents shall be designed to exclude precipitation, shall be screened toexclude birds, insects, and animals and shall terminate a minimum of 24inches above the roof. Eighteen mesh noncorrodible screen may be used.<strong>The</strong> finished water storage structure shall also be equipped with apressure-vacuum relief mechanism that will operate should the finer meshscreens be frost plugged or clogged with <strong>for</strong>eign material. <strong>The</strong> primarypurpose of the vents is to prevent catastrophic structural failure of the tankcaused by pressure differential. No modifications shall be made to ventsto interfere with this primary purpose; andc. Clearwell vents shall vent to the outside.7.0.7. Overflows on Unpressurized Finished <strong>Water</strong> Storage StructuresAll unpressurized finished water storage structures shall be provided with anoverflow. Overflows shall meet the following criteria:Aug. 29, 2003Page 135

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!