3. Technical Data<br />
Model D6-22 D80-23<br />
D100-13<br />
App. piston weight lbs. 13,670 17,640 /<br />
22,045<br />
Blows per min. 1)<br />
Minimum<br />
Maximum<br />
Energy per blow 2)<br />
Maximum<br />
Minimum<br />
Consumption 3)<br />
Diesel fuel<br />
Lubrication oil<br />
Capacity<br />
Diesel fuel<br />
Lubrication oil<br />
Weight 3)<br />
Hammer<br />
Hammer with standard<br />
guiding<br />
bl./min.<br />
bl./min.<br />
ft.lbs.<br />
ft.lbs.<br />
gal./hr.<br />
gal./hr.<br />
gal.<br />
gal.<br />
lbs.<br />
lbs.<br />
35<br />
50<br />
161,640<br />
79,200<br />
5.28<br />
0.53<br />
25.8<br />
8.3<br />
27,077<br />
29,300<br />
36<br />
45<br />
197,150<br />
246,390<br />
126,180<br />
157,685<br />
6.60 / 7.93<br />
0.68 / 0.68<br />
40.9<br />
8.4<br />
37,275<br />
44,894<br />
41,200<br />
48,800<br />
D125-32<br />
D138-32<br />
27,560 /<br />
30,420<br />
36<br />
45<br />
308,025<br />
340,000<br />
197,135<br />
217,600<br />
9.5 / 10.2<br />
0.95 / 0.95<br />
50<br />
15.8<br />
53,616<br />
57,360<br />
60,250<br />
64,000<br />
D160-32<br />
D180-32<br />
35,275 /<br />
39,680<br />
36<br />
46<br />
394,250<br />
443,500<br />
241,470<br />
271,650<br />
11.9 / 13.1<br />
1.32 / 1.32<br />
63<br />
21.1<br />
68,785<br />
75,700<br />
74,500<br />
82,600<br />
D225-22<br />
D250-22<br />
49,612 /<br />
55,050<br />
36<br />
50<br />
564,970<br />
631,351<br />
292,811<br />
331,903<br />
16.9<br />
1.53<br />
121<br />
26.4<br />
100,328<br />
106,467<br />
104,292<br />
110,431<br />
Dimensions<br />
A - Length ft. 22.6 23.6 / 24.1 25.5 / 25.9 25.8 / 26.4 26.8 / 26.7<br />
LH - Length, standard<br />
- Length with hydr. start<br />
B - Center t trip<br />
B1 - Center to trip cylinder<br />
ft.<br />
ft.<br />
inch<br />
inch<br />
24.8<br />
25.8<br />
20.0<br />
27.0<br />
28.1<br />
28.1<br />
26.0<br />
33.0<br />
27.8<br />
27.8<br />
30.5<br />
31.0<br />
25.8<br />
25.8<br />
33.7<br />
33.7<br />
26.8<br />
26.8<br />
29.5<br />
29.5<br />
C - Center to pump guard inch 25.5 23.0 22.5 24.5 27.56<br />
D - Width of hammer<br />
D1 - With of trip<br />
inch<br />
inch<br />
32.5<br />
35.5<br />
35.0<br />
47.5<br />
41.0<br />
47.5<br />
45.5<br />
51.2<br />
W - Min. lead width inch 32 42* 42* 48* 54*<br />
53.55<br />
43.31<br />
1. Depends on fuel pump setting, type of soil and type of pile<br />
2. Potential energy calculated by multiplying piston weight and stroke. The stroke of the ram is a result of the blow rate<br />
3. Consumption and weights are approximate, weight of guiding depends on type and size<br />
111 Berry Road<br />
Houston, TX 77002<br />
Tel. (713) 691-3000<br />
Fax (713) 691-0089<br />
E-mail: info@bauerpileco.com<br />
www.bauerpileco.com<br />
<strong>Operations</strong> <strong>Manual</strong> December 2012<br />
15