15.09.2015 Views

Twido Programmable controller

Twido programmable controller - Mejdaf Group

Twido programmable controller - Mejdaf Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Curves (continued)<br />

Connection interfaces 0<br />

Advantys Telefast ABE 7 pre-wired system<br />

Connection sub-bases for <strong>Twido</strong> <strong>controller</strong><br />

Electrical durability (in millions of operating cycles, conforming to IEC 60947-5-1)<br />

ABE 7B20MRM20 and ABE 7E16SRM20<br />

d.c. loads<br />

DC 12 curves (1) DC 13 curves (2)<br />

Millions of<br />

operating cycles<br />

0,50<br />

0,45<br />

0,40<br />

230V<br />

0,35<br />

110V<br />

0,30<br />

0,25<br />

0,20<br />

48V<br />

0,15<br />

0,10<br />

0,05<br />

0,00<br />

0,25 0,50<br />

0,75 1 1,25<br />

1,50<br />

1,75<br />

2<br />

Current A<br />

Millions of<br />

operating cycles<br />

2,0<br />

1,8<br />

1,6<br />

1,4<br />

1,2<br />

1,0<br />

0,8<br />

230V<br />

110V<br />

48V<br />

0,6<br />

24V<br />

0,4<br />

0,2<br />

0,0<br />

0 0,2<br />

0,4 0,6<br />

0,8<br />

1<br />

Current A<br />

a.c. loads<br />

AC 12 curves (3) AC 14 curves (4)<br />

Millions of<br />

operating cycles<br />

1,50<br />

1,25<br />

1,00<br />

0,75<br />

0,50<br />

0,25<br />

0,00<br />

0<br />

0,5<br />

24V<br />

48V<br />

110V<br />

230V<br />

1 1,5<br />

2<br />

Current A<br />

Millions of<br />

operating cycles<br />

1,0<br />

0,9<br />

0,8<br />

0,7<br />

0,6<br />

0,5<br />

0,4<br />

0,3<br />

0,2<br />

0,1<br />

0,0<br />

0<br />

L/R = 10ms 48V<br />

L/R = 10ms 24V<br />

L/R = 60ms 48V<br />

L/R = 60ms 24V<br />

0,2 0,4 0,6<br />

0,8<br />

1<br />

Current A<br />

AC 15 curves (5)<br />

Millions of<br />

operating cycles<br />

1,0<br />

0,9<br />

0,8<br />

0,7<br />

0,6<br />

0,5<br />

0,4<br />

0,3<br />

0,2<br />

0,1<br />

0,0<br />

0<br />

0,5<br />

24V<br />

48V<br />

1 1,5<br />

2<br />

Current A<br />

(1) DC 12: control of resistive loads and of solid state loads isolated by optocoupler, L/R ≤ 1 ms.<br />

(2) DC 13: control of electromagnets, L/R ≤ 2 x (Ue x Ie) in ms, Ue: Rated operational voltage, Ie: rated operational current (with a protective diode on the load, DC12<br />

curves must be used with a coefficient of 0.9 applied to the number in millions of operating cycles)<br />

(3) AC 12: control of resistive loads and of solid state loads isolated by optocoupler, cos ϕ ≤ 0.9.<br />

(4) AC 14: control of small electromagnetic loads ≤72 VA, make: cos ϕ = 0.3, break: cos ϕ = 0.3.<br />

(5) AC 15: control of electromagnetic loads > 72 VA, make: cos ϕ = 0.7, break: cos ϕ = 0.4.<br />

Presentation :<br />

page 96<br />

Compatibility :<br />

page 97<br />

Characteristics :<br />

pages 98 and 99<br />

References, dimensions :<br />

pages 102 and 103<br />

Schemes :<br />

pages 104 to 107<br />

101